Development of Ratiometric Fluorescent Biosensors for the Determination of Creatine and Creatinine in Urine

نویسندگان

  • Hong Dinh Duong
  • Jong Il Rhee
چکیده

In this study, the oxazine 170 perchlorate (O17)-ethylcellulose (EC) membrane was successfully exploited for the fabrication of creatine- and creatinine-sensing membranes. The sensing membrane exhibited a double layer of O17-EC membrane and a layer of enzyme(s) entrapped in the EC and polyurethane hydrogel (PU) matrix. The sensing principle of the membranes was based on the hydrolytic catalysis of urea, creatine, and creatinine by the enzymes. The reaction end product, ammonia, reacted with O17-EC membrane, resulting in the change in fluorescence intensities at two emission wavelengths (λem = 565 and 625 nm). Data collected from the ratio of fluorescence intensities at λem = 565 and 625 nm were proportional to the concentrations of creatine or creatinine. Creatine- and creatinine-sensing membranes were very sensitive to creatine and creatinine at the concentration range of 0.1-1.0 mM, with a limit of detection (LOD) of 0.015 and 0.0325 mM, respectively. Furthermore, these sensing membranes showed good features in terms of response time, reversibility, and long-term stability. The interference study demonstrated that some components such as amino acids and salts had some negative effects on the analytical performance of the membranes. Thus, the simple and sensitive ratiometric fluorescent sensors provide a simple and comprehensive method for the determination of creatine and creatinine concentrations in urine.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

A stable three enzyme creatinine biosensor. 2. Analysis of the impact of silver ions on creatine amidinohydrolase.

The enzyme creatine amidinohydrolase is a clinically important enzyme used in the determination of creatinine in blood and urine. Continuous use biosensors are becoming more important in the clinical setting; however, long-use creatinine biosensors have not been commercialized due to the complexity of the three-enzyme creatinine biosensor and the lack of stability of its components. This paper,...

متن کامل

Amperometric biosensor based on reductive H2O2 detection using pentacyanoferrate-bound polymer for creatinine determination.

Pentacyanoferrate-bound poly(1-vinylimidazole) (PVI[Fe(CN)5]) was selected as a mediator for amperometric creatinine determination based on the reductive H2O2 detection. Creatinine amidohydrolase (CNH), creatine amidohydrolase (CRH), sarcosine oxidase (SOD), peroxidase (POD), and PVI[Fe(CN)5] were crosslinked with poly(ethylene glycol) diglycidyl ether (PEGDGE) on a glassy carbon (GC) electrode...

متن کامل

Fluorimetric determination of creatine.

STRONGLY ALKALINE SOLUTIONS ninhydrin (1,2,3 indantrione hy) combines with guanidine, monosubstituted guanidines, and disubstituted guanidines to form highly fluorescent addition ucts (1). This reaction has been used as the basis for a simple, itive fluorimetric method for the determination of creatine in m, blood, and urine. he most widely used methods for determining creatine are based n the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017