Comparative two - and four - probe impedance measurements on BICUVOX
نویسندگان
چکیده
In two-probe impedance measurements the interfacial impedance between metal electrode and ionic conductor contributes to the measured impedance. Therefore a calculation procedure which separates the bulk from the interfacial impedance must be applied. The separation procedure can be avoided by measuring the bulk conductivity in the four-probe arrangement. The impedance of polycrystalline samples and single crystals of the oxygen ion conductor BICUVOX.10 was measured in the 6 a.c. twoand four-probe configuration. The frequency range was 0.1 to 1 3 10 Hz in the case of two-probe measurements 5 and 0.1 to 1 3 10 Hz in the case of four-probe measurements. For single crystals, impedance spectra were taken in the direction parallel to the oxygen-conducting layers. The results of bulk conductivity obtained by fourand two-probe measurements were in agreement for polycrystalline samples and for single crystals. The origin of inductive loops visible for single crystals in the impedance spectra taken by the four-probe method is explained in a qualitative fashion as an interfacial effect at the voltage electrodes. 1999 Elsevier Science B.V. All rights reserved.
منابع مشابه
Measurement of Bulk Resistance of Conducting Polymer Films in Presence of Rectifying Contacts
Measurement of bulk resistance/resistivity of conducting polymers is very common and an important requirement. Conducting polymers are semiconductors and four probe measurements are needed to avoid errors due to contact resistance and spreading resistances. However, in a device it is convenient to make two probe measurements rather than four probe measurement. It has been shown here that the bu...
متن کاملFirst mesospheric in-situ measurement in Iran using sounding rockets and plasma impedance probe (PIP)
This paper reports on the progress for the first development of rocket probe for in-situ measurement of ionospheric plasma parameters in Iran. The designed probe known as Plasma Impedance Probe (PIP) will be used to measure the electron density, electron-neutral collision frequency, background magnetic field, and temperature in the mesospheric and in the altitude range of 70 km to 150 km. This ...
متن کاملVoltammetric measurements on Me O ( Me 5 Bi , Cu , V ) x y compounds and comparison with results for BICUVOX . 10
Voltammetric measurements on cells of arrangement Pt,ArusampleuYSZuAr,Pt with a very small sample mass (‘microsamples’) turned out to be a very convenient tool for the determination of thermodynamic properties of oxides. Measurements were made on Bi O , CuO and V O microsamples and on nickel and copper metal between 550 and 7008C. The 2 3 2 5 measurements on nickel were used for the calibration...
متن کاملStudy of grain boundary polarization by two-probe and four-probe impedance spectroscopy
Four-probe impedance spectra of polycrystalline cation conductors: NASICON, Na b0-alumina and Ag b0-alumina, were measured in the frequency range from 10 Hz to 100 kHz with the aid of high sensitivity, high input impedance preamplifiers. Dispersion associated with the grain boundary polarization was observed below room temperature. The frequency dependent part of the conductivity of grain inter...
متن کاملConsiderations on electrical impedance measurements of electrolyte solutions in a four- electrode cell
A tetrapolar probe to measure the electrical properties of electrolyte solutions was implemented with gold electrodes according to the van der Pauw method. Electrical impedance spectroscopy (EIS) measurements of different concentrations of phosphate buffer saline (PBS) solution and an oral mucosal tissue sample dispersed in PBS were performed in the galvanostatic mode using a four-electrode cel...