Transoesophageal echocardiography in cardiac and vascular surgery: implications and observer variability.

نویسندگان

  • D Schmidlin
  • D Bettex
  • E Bernard
  • R Germann
  • M Tornic
  • R Jenni
  • E R Schmid
چکیده

Transoesophageal echocardiography (TOE) has gained widespread acceptance among cardiac anaesthetists as a tool to facilitate peri-operative decision-making. This observational study analyses the impact of TOE and its inter-observer variability on intra-operative patient management during cardiac and major vascular surgery. From June 1996 to December 1998, standardized reports were obtained from 11 anaesthetists in 1891 adult cardiac and vascular surgery patients undergoing routine biplane or multiplane TOE. Inter-observer variability and the difference between variables of interest were tested using the chi-squared test or factorial analysis of variance as appropriate. TOE examinations were performed before and after the operation; 1,673 (88.5%) patients underwent cardiopulmonary bypass (CPB), and 218 (11.5%) patients had surgery without CPB, including 42 (2.2%) coronary revascularizations. In 923 patients (49%), TOE provided additional information that influenced the patient's therapy. In 968 patients (51%), TOE had only minor or no impact on clinical decision-making. In two patients (0.10%) the scheduled operation was not performed, and in another two patients the TOE examination led to major complications. Observer-dependent variables were: implications of TOE for intraoperative decision-making (P<0.0001), estimation of image quality (P < 0.0001), pre-operative left ventricular fractional area change (FAC) (P = 0.0026), difference between pre-operative FAC and post-operative FAC (P = 0.033), and requests for supervision (P < 0.0001). There was no significant difference in the case mix between observers. TOE had an important impact on intraoperative patient management. Inter-observer variability was significant for several variables but not for the frequency of additional surgical procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

Left ventricular volume and ejection fraction assessment with transoesophageal echocardiography: 2D vs 3D imaging.

BACKGROUND Developments in transducer technology have enabled the use of three-dimensional transoesophageal echocardiography (3D TOE) in the operating theatre. Transthoracic echocardiography (TTE) 3D left ventricular (LV) volumes and ejection fraction (EF) agree better with magnetic resonance imaging (MRI) measurements, with less intra- and inter-observer variability compared with 2D. This has ...

متن کامل

Audit of anaesthetist-performed echocardiography on perioperative management decisions for non-cardiac surgery.

BACKGROUND Intraoperative transoesophageal echocardiography is increasingly used for guiding intraoperative management decisions during non-cardiac surgery. Transthoracic echocardiography (TTE) equipment and training is becoming more available to anaesthetists, and its point-of-care application may facilitate real-time haemodynamic management and preoperative screening. METHODS We conducted a...

متن کامل

Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography. Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiogr...

متن کامل

Early post operative mortality of Total Correction of Tetralogy of Fallot

Introduction: Since 1954, after the first surgical repair of tetralogy of Fallot (TOF), several innovations have occurred in cardiac surgery, especially in children. One stage complete repair of TOF is currently possible even in infancy; however, complications such as hypoxemia, arrhythmia, cardiac dysfunction, sudden death, and valvular disorders may happen. In this study, we evaluated the res...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 86 4  شماره 

صفحات  -

تاریخ انتشار 2001