Are Portable Imaging Intraoperative Radiographs Helpful for Assessing Adequate Acetabular Cup Positioning in Total Hip Arthroplasty?

نویسندگان

  • Sang Won Park
  • Jong Hoon Park
  • Seung-Beom Han
  • Gi Won Choi
  • Dong Ik Song
  • Eun Soo An
چکیده

Despite advances in surgical techniques and instrumentation, current intra-operative estimations of acetabular version in total hip arthroplasty are of limited accuracy. In the present study, two experienced orthopedic surgeons compared intra-operatively measured (using portable imaging) anteversions and vertical inclinations of acetabular components with those measured using standardized radiographs post-operatively in 40 patients. Of the all vertical inclinations measured from intra-operative radiographs, 72.5% (n=29) were within +/-2 degrees , and 97.5% (n=39) were within +/-5 degrees of those determined using post-operative radiographs, and for anteversion, 52.5% (n=21) were within +/-2 degrees , and 97.5% (n=39) were within +/-5 degrees . Post-operative radiographs demonstrated that 90.0% (n=36) of vertical inclinations and anteversions were within the adequate zone. Obviously, our method has its limitations, but the authors conclude that the method described in this article better allows surgeons to verify acetabular version intra-operatively. In particular, the described method is suitable in cases with a deformed acetabular anatomy and difficult revision surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluoroscopic Imaging of Acetabular Cup Position During THA Through a Direct Anterior Approach

Two main causes of postoperative total hip arthroplasty (THA) dislocation are malposition of the acetabular component within the prosthesis and soft tissue imbalances.1 The direct anterior approach for THA is viewed as advantageous compared with other approaches because, in addition to preserving many of the inherent restraints within the hip joint,2 it allows C-arm fluoroscopy image intensifie...

متن کامل

Measuring Acetabular Cup Orientation on Antero-Posterior Radiographs of the Hip after Total Hip Arthroplasty with a Vector Arithmetic Radiological Method. Is It Valid and Verified for Daily Clinical Practice?

PURPOSE The aim of this prospective study is to validate a vector arithmetic method for measuring acetabular cup orientation after total hip arthroplasty (THA) and to verify the clinical practice. MATERIALS AND METHODS We measured cup anteversion and inclination of 123 patients after cementless primary THA twice by two examiners on AP pelvic radiographs with a vector arithmetic method and com...

متن کامل

Fluoroscopic imaging of acetabular cup position during THA through a direct anterior approach.

Mobile image intensifiers are more readily used to assess acetabular cup placement when performing a total hip arthroplasty through a direct anterior approach. However, patient positioning affects pelvic tilt and rotation, which in turn requires proper C-arm fluoroscopy adjustments for image interpretation. The authors provide insight into the interpretation of acetabular cup positioning based ...

متن کامل

The Usefulness of Three-dimensional Computed Tomography as an Assessment of Periacetabular Osteolysis in Revision Total Hip Arthroplasty

PURPOSE This study was performed to determine the usefulness of three-dimensional computed tomography (3D-CT) in measuring periacetabular osteolysis by comparing the real volume of osteolysis in revision surgery. MATERIALS AND METHODS Twnety-three patients who had undergone revision surgery due to periacetabular osteolysis but not included septic osteolysis and implant loosening. The mean age...

متن کامل

Obesity does not necessarily affect the accuracy of acetabular cup implantation in total hip replacement.

Postoperative radiographs of 111 patients who had undergone cemented total hip replacement performed or supervised by a single surgeon were analysed. All surgeries were performed via an anterolateral approach with patients in the lateral position. Patients were stratified according to Body Mass Index (BMI) into three groups (healthy, overweight and obese) and acetabular cup angles were measured...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 24  شماره 

صفحات  -

تاریخ انتشار 2009