Effects of Propofol on Respiratory Drive and Patient-ventilator Synchrony during Pressure Support Ventilation in Postoperative Patients: A Prospective Study
نویسندگان
چکیده
BACKGROUND Propofol is increasingly used during partial support mechanical ventilation such as pressure support ventilation (PSV) in postoperative patients. However, breathing pattern, respiratory drive, and patient-ventilator synchrony are affected by the sedative used and the sedation depth. The present study aimed to evaluate the physiologic effects of varying depths of propofol sedation on respiratory drive and patient-ventilator synchrony during PSV in postoperative patients. METHODS Eight postoperative patients receiving PSV for <24 h were enrolled. Propofol was administered to achieve and maintain a Ramsay score of 4, and the inspiratory pressure support was titrated to obtain a tidal volume (VT) of 6-8 ml/kg. Then, the propofol dose was reduced to achieve and maintain a Ramsay score of 3 and then 2. At each Ramsay level, the patient underwent 30-min trials of PSV. We measured the electrical activity of the diaphragm, flow, airway pressure, neuro-ventilatory efficiency (NVE), and patient-ventilator synchrony. RESULTS Increasing the depth of sedation reduced the peak and mean electrical activity of the diaphragm, which suggested a decrease in respiratory drive, while VT remained unchanged. The NVE increased with an increase in the depth of sedation. Minute ventilation and inspiratory duty cycle decreased with an increase in the depth of sedation, but this only achieved statistical significance between Ramsay 2 and both Ramsay 4 and 3 (P < 0.05). The ineffective triggering index increased with increasing sedation depth (9.5 ± 4.0%, 6.7 ± 2.0%, and 4.2 ± 2.1% for Ramsay 4, 3, and 2, respectively) and achieved statistical significance between each pair of depth of sedation (P < 0.05). The depth of sedation did not affect gas exchange. CONCLUSIONS Propofol inhibits respiratory drive and deteriorates patient-ventilator synchrony to the extent that varies with the depth of sedation. Propofol has less effect on breathing pattern and has no effect on VT and gas exchange in postoperative patients with PSV.
منابع مشابه
Effects of dexmedetomidine and propofol on patient-ventilator interaction in difficult-to-wean, mechanically ventilated patients: a prospective, open-label, randomised, multicentre study
BACKGROUND Dexmedetomidine can be used for sedation of mechanically ventilated patients and has minor respiratory effects. The aim of this study was to compare the incidence of patient-ventilator dyssynchronies during sedation with dexmedetomidine or propofol. METHODS We conducted a multicentre, prospective, open-label, randomised clinical trial, comparing dexmedetomidine with standard propof...
متن کاملNew modalities for non-invasive positive pressure ventilation: A review article
Efficiency of non-invasive positive pressure ventilation in the treatment of respiratory failure has been shown in many published studies. In this review article, we introduced new modalities of non-invasive ventilation (NIV), clinical settings in which NIV can be used and a practical summary of the latest official guidelines published by the European Respiratory Clinical Practice. Clinical tri...
متن کاملSedation with etomidate-fentanyl versus propofol-fentanyl in colonoscopies: A prospective randomized study
Abstract Background: The combination of propofol-fentanyl for sedation during colonoscopy is characterized by the frequent incidence of side effects. Etomidate-fentanyl provides fewer hemodynamic and respiratory complications. The aim of our study was to compare the safety and efficacy of propofol-fentanyl and etomidate-fentanyl for conscious sedation in elective colonoscopy. Methods: This do...
متن کاملInfluence of different interfaces on synchrony during pressure support ventilation in a pediatric setting: a bench study.
BACKGROUND In adults and children, patient-ventilator synchrony is strongly dependent on both the ventilator settings and interface used in applying positive pressure to the airway. The aim of this bench study was to determine whether different interfaces and ventilator settings may influence patient-ventilator interaction in pediatric models of normal and mixed obstructive and restrictive resp...
متن کاملAsynchrony and dyspnea.
Patient-ventilator synchrony and patient comfort are assumed to go hand in hand, yet few studies provide support for this common sense idea. In reality, synchrony between the patient and ventilator is complex and can be affected by the ventilator settings, type of ventilator, patient-ventilator interface, and sedation. Inspections of airway pressure and flow waveforms are reliable methods for d...