Proposed STAR Time of Flight Readout Electronics and DAQ
نویسنده
چکیده
The Time-of-Flight system is a proposed addition to the STAR detector currently installed at RHIC. The proposal is based on a new technology called the Multi-gap Resistive Plate Chamber (MRPC), and consists of approximately 23,000 channels of detectors distributed over 120 trays. Each TOF tray consists of 192 detector channels and three different types of electronic circuit cards, called “TFEE”, “TDIG”, and “TCPU”, listed in order of the data flow. Every fourth tray also contains a “TMIT” card that transmits the data over a fiber to the TDRC which is part of STAR DAQ. The TFEE contains the analog front end electronics. The output of TFEE is passed to the TDIG, where the data are digitized (using the CERN HPTDC ASIC). The TCPU formats and buffers the digital detector information. This formatted data is passed to TMIT, which transmits it over an optical fiber to the data receiver TDRC in the STAR DAQ room. The architecture of this readout chain and DAQ will be described, and first results from prototypes of the component boards will be discussed.
منابع مشابه
Closed-Loop Compensation of the Quadrature Error in MEMS Vibratory Gyroscopes
In this paper, a simple but effective method for compensation of the quadrature error in MEMS vibratory gyroscope is provided. The proposed method does not require any change in the sensor structure, or additional circuit in the feedback path. The mathematical relations of the proposed feedback readout system were analyzed and the proposed solution assures good rejection capabilities. Based on ...
متن کاملThe Cathode Strip Chamber Data Acquisition System for CMS
The Cathode Strip Chamber (CSC) [1] Data Acquisition (DAQ) system for the CMS [2] experiment at the LHC [3] will be described. The CSC system is large, consisting of 218K cathode channels and 183K anode channels. This leads to a substantial data rate of ~1.5GByte/s at LHC design luminosity (10cms) and the CMS first level trigger (L1A) rate of 100KHz. The DAQ system consists of three parts. The ...
متن کاملA Readout IC Using Two-Step Fastest Signal Identification for Compact Data Acquisition of PET Systems
A readout integrated circuit (ROIC) using two-step fastest signal identification (FSI) is proposed to reduce the number of input channels of a data acquisition (DAQ) block with a high-channel reduction ratio. The two-step FSI enables the proposed ROIC to filter out useless input signals that arise from scattering and electrical noise without using complex and bulky circuits. In addition, an asy...
متن کاملCombining endoscopic ultrasound with Time-Of-Flight PET: The EndoTOFPET-US Project
The EndoTOFPET-US collaboration develops a multimodal imaging technique for endoscopic exams of the pancreas or the prostate. It combines the benefits of high resolution metabolic imaging with Time-OfFlight Positron Emission Tomography (TOF PET) and anatomical imaging with ultrasound (US). EndoTOFPET-US consists of a PET head extension for a commercial US endoscope and a PET plate outside the b...
متن کاملThe IFR Online Detector Control system at the BaBar experiment
The Instrumented Flux Return (IFR)[1] is one of the five subdetectors of the BaBar[2] experiment on the PEP II accelerator at SLAC. The IFR consists of 774 Resistive Plate Chamber (RPC) detectors, covering an area of about 2,000 m2 and equipped with 3,000 Front-end Electronic Cards (FEC) reading about 50,000 channels (readout strips). The first aim of a B-factory experiment is to run continuous...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -