Studies of left ventricular volume estimation from gated blood pool scan with the use of regression equations.

نویسندگان

  • Y Hiraki
  • H Yanagi
  • I Nagaya
  • M Shimizu
  • I Joja
  • K Aono
چکیده

The authors carried out experimental and clinical studies of left ventricular volume measurement using equilibrium-gated blood pool scan. Using phantoms, we experimentally obtained a regression equation between radioisotope levels and camera counts. From this equation, we deduced a regression equation between camera counts and volumes, which was then used for calculation of left ventricular volumes using count technique. In an experiment using phantom with various volumes, we obtained a favorable result that the average absolute error between the true and measured volumes was as small as 6.8%. In 11 patients, we calculated the left ventricular volume and ejection fraction employing the regression equation and compared the calculated values with the values obtained by cinemascopy. This comparison disclosed an excellent correlation (r = 0.955 for end-diastolic volume, 0.997 for end-systolic volume and 0.853 for ejection fraction). Mean absolute error was 16.2% for end-diastolic volume and 16.0% for end-systolic volume. These results indicate that this technique is clinically applicable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scintiphotographic evaluation of patients with suspected left ventricular aneurysm.

aneurysm were evaluated by routine clinical studies, gated cardiac blood pool scanning, and contrast left ventriculography. Thirteen patients were found to have a localized left ventricular aneurysm and nine demonstrated diffuse left ventricular hypokinesis on contrast angiography. The patients with localized left ventricular aneurysms could not be separated from those with diffuse left ventric...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Evaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software

Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...

متن کامل

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

Measurement of absolute left ventricular volume from gated blood pool studies.

was given by the ratio of the attenuation-corrected end-diastolic count rate from the gated study to the count rate per milliliter from a blood sample. Attenuation correction was made by dividing the end-diastolic count rate by e ud, where u = the linear attenuation coefficient of water and d = the distance from the skin marker to the center of the left ventricle in the anterior view divided by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radioisotopes

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 1987