Hypertrophic cardiomyopathy: role of the implantable cardioverter-defibrillator.
نویسندگان
چکیده
OBJECTIVES We report the occurrence of cardiac events during long-term follow-up in patients with hypertrophic cardiomyopathy (HCM) after cardioverter-defibrillator implantation. BACKGROUND The identification of patients at high risk for sudden death and the prevention of recurrence of sudden death in HCM represents a difficult problem. METHODS We retrospectively analyzed the occurrence of cardiac events during follow-up of 13 patients with HCM who received an implantable cardioverter-defibrillator (ICD) because of aborted sudden death (n = 10) or sustained ventricular tachycardia (n = 3) (group I). Findings were compared with those in 215 patients with an ICD and other structural heart disease or idiopathic ventricular fibrillation (group II). RESULTS After a mean (+/-SD) follow-up period of 26+/-18 months, 2 of 13 patients in group I received appropriate shocks. The calculated cumulative incidence of shocks was 21% in group I and 66% in group II after 40 months (p < 0.05). We observed a low incidence of recurrence of ventricular tachycardia/fibrillation during follow-up in patients with HCM. No deaths occurred. CONCLUSIONS Our data suggest that ventricular tachyarrhythmias may not always be the primary mechanism of syncope and sudden death in patients with HCM. The ICD seems to have a less important impact on prognosis in patients with HCM than in patients with other etiologies of aborted sudden death.
منابع مشابه
Implantable cardioverter-defibrillator in pregnant women with hypertrophic cardiomyopathy.
We describe the successful implantation of a cardioverter-defibrillator (ICD) in two pregnant women with hypertrophic cardiomyopathy at high risk. The indication of ICD and the necessary care for ICD implantation during pregnancy are discussed and were the main objectives of this case report.
متن کاملRole of Implantable Cardioverter Defibrillators in the Treatment of Hypertrophic Cardiomyopathy
Hypertrophic cardiomyopathy (HCM) is an important cardiovascular disease with sudden cardiac death as the most devastating presentation. Implantable cardioverter defibrillators (ICD) are the optimal therapy for prevention of sudden death from ventricular tachycardia or fibrillation of any cause. While there is no controversy with implanting ICDs in patients who have already survived a cardiac a...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کامل[Cardiac arrest in the pediatric population].
A case of cardiac arrest in a ten year old child that was successfully resuscitated is here presented. The etiological investigation showed an Hypertrophic Cardiomyopathy (HCM). An Implantable Cardioverter Defibrillator (ICD) was placed for secondary profilaxy of Sudden Death (SD). Sudden Death in paediatric age is a rare accident with bad prognosis (survival with no sequel inferior to 5%) and ...
متن کاملSurface fragmented QRS in a patient with hypertrophic cardiomyopathy and malignant arrhythmias: Is there an association?
An 18- year old woman with hypertrophic cardiomyopathy, aborted sudden cardiac death and implanted with an implantable cardioverter defibrillator (ICD), developed progressive fragmentation of her surface 12-lead electrocardiogram (ECG). During the follow-up, she presented with multiple appropriate ICD discharges. Here, we discuss the possible association between surface fragmented ECG and the r...
متن کاملAtypical position of subcutaneus implantable cardioverter-defibrillator as a solution in hypertrophic cardiomyopathy patient with initially negative electrocardiographic screening.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/eurheartj/ehv209 Online publish-ahead-o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 31 5 شماره
صفحات -
تاریخ انتشار 1998