Novel electrochemical methodology for activity estimation of alkaline phosphatase based on solubility difference.

نویسندگان

  • Kosuke Ino
  • Yusuke Kanno
  • Toshiharu Arai
  • Kumi Y Inoue
  • Yasufumi Takahashi
  • Hitoshi Shiku
  • Tomokazu Matsue
چکیده

We propose a novel electrochemical detection system for alkaline phosphatase (ALP) activity using the difference in water and oil solubilities between the substrate, ferrocene ethyl phosphate ester (FcEtOPO(3)(2-)), and the enzymatic product, ferroceneethanol (FcEtOH). In this system, water droplets containing ALP and FcEtOPO(3)(2-) were placed on a Pt disk microelectrode and surrounded by a mineral oil. By the ALP-catalyzed reaction, FcEtOPO(3)(2-) was converted to FcEtOH, which was then transferred to the mineral oil from the water droplets with FcEtOPO(3)(2-) remaining in the water droplets. After partitioning FcEtOH from the water droplets, FcEtOPO(3)(2-) was detected at the Pt disk microelectrode to estimate the ALP activity. Using this novel system, the ALP activity of embryoid bodies was successfully detected. We believe that the present system will be widely applicable to ALP-based bioassays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Alkaline Phosphatase Lacking Wheat Germ Agglutinin Binding Sites Useful Enzyme for Lectin Assays with Comparable Activity to the Calf Enzyme

Despite the availability of various alkaline phosphatase (ALP) isoenzymes, the calf enzyme is being used in current enzyme assays as the detector enzyme. The glycosylation pattern of this enzyme makes it a suitable ligand for binding to wheat germ agglutinin lectin (WGA). As a result of this property, the enzyme can not be used as a conjugate with this lectin, and the calf enzyme conjugates can...

متن کامل

The effects of chromium and cadmium on the activity of alkaline phosphatase lsoenzmes in rats

The aim of this study was to Investigate the toxic effects of chromium and cadmium on the activity of two isoenzymes of alkaline phosphatase in vitro and in vivo experiments. Oral administration and peritoneal injection of  CdCl2 or CrCl3 in rats reduced serum alkaline phosphatase by 21.5℅ and 25.5℅ respectively. At the same time high molecular weight alkaline phosphatase was elevated by 138℅ a...

متن کامل

Ratiometric electrochemical detection of alkaline phosphatase.

A novel ferrocene-derived substrate for the ratiometric electrochemical detection of alkaline phosphatase (ALP) was designed and synthesised. It was demonstrated to be an excellent electrochemical substrate for the ALP-labelled enzyme-linked immunosorbent assay (ELISA).

متن کامل

Highly sensitive electrochemical detection of proteins using aptamer-coated gold nanoparticles and surface enzyme reactions.

A novel electrochemical detection methodology is described for the femtomolar detection of proteins which utilizes both DNA aptamer-functionalized nanoparticles and a surface enzymatic reaction. Immunoglobulin E (IgE) was used as a model protein biomarker, which possesses two distinct epitopes for antibody (anti-IgE) and DNA aptamer binding. A surface sandwich assay format was utilized involvin...

متن کامل

A novel aptasensor for thrombin detection based on alkaline phosphatase decorated ZnO/Pt nanoflowers as signal amplifiers.

To remedy the problems caused by the introduction of an additional electron mediator and realize signal amplification, a new strategy has been presented to construct an electrochemical aptasensor for thrombin detection based on the cascade electrocatalysis of alkaline phosphatase (ALP) and Pt nanoparticle (PtNP)-functionalized ZnO nanoflowers.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 84 18  شماره 

صفحات  -

تاریخ انتشار 2012