A high-throughput, multiplexed microfluidic method utilizing an optically barcoded drop library The power of drop-based microfluidics promises reduced biological assaying times and greater sample

ثبت نشده
چکیده

The power of drop-based microfluidics promises reduced biological assaying times and greater sample throughput; however, current drop-based microfluidic methods focus on single-input single-output techniques to provide these benefits. In order to achieve truly high-throughput analysis of biological assays, a multiple-input approach must be taken. This thesis is focused on developing and validating a drop-based microfluidic method that is capable of encapsulating, in parallel, 96 assay samples in drops and optically tracking them in a barcoded drop library. The advantage of the method presented here is its ability to be integrated with current biological assays performed on a 384-well plate. The first step was to fabricate a three-dimensional microfluidic device capable of accepting 96 sample inputs. Second, formation of drops within the device was characterized by creating a state diagram using Capillary and Weber numbers of the two phase flow. Finally, the use of fluorescent microbeads was investigated for the purpose of optically barcoding drops. A barcoding scheme was developed to allow for fluorescent and spatial labeling of 96 wells of a 384-well plate. The three-dimensional microfluidic device was successfully used to encapsulate 50 μm diameter drops from 24 wells barcoded with fluorescent microbeads at a drop formation rate of 3 kHz per well. Fluorescent detection of the barcoded drop mixture was performed at a rate of 200 Hz and density-based clustering algorithm DBSCAN was used to identify barcoded drop clusters from the fluorescent signal data. Validation of this method was achieved by adding known concentrations of fluorescent blue microbeads to barcoded wells and detecting for their presence in barcoded drop clusters. The barcoding method can be expanded to fully incorporate the 96 inputs of the microfluidic device by adding a spatial barcoding component to each quadrant of 24 optically barcoded wells. The results presented here show the microfluidic platform has the potential to be a useful tool in biological assays involved with tracking a large number of samples in a well plate format.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Drop-Based Microfluidics for Biological Applications

Drop-based microfluidic technology has been attracting great attention since the prevalence of soft-lithography techniques in poly-dimethylsiloxane (PDMS) microfluidic device fabrication a decade ago. The miniaturized isolated confinement of the droplet provides an ideal environment to study single cell behaviors in vitro that might otherwise be buried in the ensemble measurements. The effectiv...

متن کامل

Coalescing drops in microfluidic parking networks: A multifunctional platform for drop-based microfluidics.

Multiwell plate and pipette systems have revolutionized modern biological analysis; however, they have disadvantages because testing in the submicroliter range is challenging, and increasing the number of samples is expensive. We propose a new microfluidic methodology that delivers the functionality of multiwell plates and pipettes at the nanoliter scale by utilizing drop coalescence and confin...

متن کامل

High-Throughput Single-Cell Labeling (Hi-SCL) for RNA-Seq Using Drop-Based Microfluidics

The importance of single-cell level data is increasingly appreciated, and significant advances in this direction have been made in recent years. Common to these technologies is the need to physically segregate individual cells into containers, such as wells or chambers of a micro-fluidics chip. High-throughput Single-Cell Labeling (Hi-SCL) in drops is a novel method that uses drop-based librari...

متن کامل

A mix-and-read drop-based in vitro two-hybrid method for screening high-affinity peptide binders

Drop-based microfluidics have recently become a novel tool by providing a stable linkage between phenotype and genotype for high throughput screening. However, use of drop-based microfluidics for screening high-affinity peptide binders has not been demonstrated due to the lack of a sensitive functional assay that can detect single DNA molecules in drops. To address this sensitivity issue, we in...

متن کامل

High-throughput sorting of drops in microfluidic chips using electric capacitance.

We analyze a recently introduced approach for the sorting of aqueous drops with biological content immersed in oil, using a microfluidic chip that combines the functionality of electrowetting with the high throughput of two-phase flow microfluidics. In this electrostatic sorter, three co-planar electrodes covered by a thin dielectric layer are placed directly below the fluidic channel. Switchin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016