A comparison of physiologic modulators of fMRI signals.

نویسندگان

  • Peiying Liu
  • Andrew C Hebrank
  • Karen M Rodrigue
  • Kristen M Kennedy
  • Denise C Park
  • Hanzhang Lu
چکیده

One of the main obstacles in quantitative interpretation of functional magnetic resonance imaging (fMRI) signal is that this signal is influenced by non-neural factors such as vascular properties of the brain, which effectively increases signal variability. One approach to account for non-neural components is to identify and measure these confounding factors and to include them as covariates in data analysis or interpretation. Previously, several research groups have independently identified four potential physiologic modulators of fMRI signals, including baseline venous oxygenation (Yv ), cerebrovascular reactivity (CVR), resting state BOLD fluctuation amplitude (RSFA), and baseline cerebral blood flow (CBF). This study sought to directly compare the modulation effects of these indices in the same fMRI session. The physiologic parameters were measured with techniques comparable with those used in the previous studies except for CBF, which was determined globally with a velocity-based phase-contrast MRI (instead of arterial-spin-labeling MRI). Using an event-related, scene-categorization fMRI task, we showed that the fMRI signal amplitude was positively correlated with CVR (P < 0.0001) and RSFA (P = 0.002), while negatively correlated with baseline Yv (P < 0.0001). The fMRI-CBF correlation did not reach significance, although the (negative) sign of the correlation was consistent with the earlier study. Furthermore, among the physiologic modulators themselves, significant correlations were observed between baseline Yv and baseline CBF (P = 0.01), and between CVR and RSFA (P = 0.05), suggesting that some of the modulators may partly be of similar physiologic origins. These observations as well as findings in recent literature suggest that additional measurement of physiologic modulator(s) in an fMRI session may provide a practical approach to control for inter-subject variations and to improve the ability of fMRI in detecting disease or medication related differences. Hum Brain Mapp 34:2078-2088, 2013. © 2011 Wiley Periodicals, Inc.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Physiologic Modulators in Event-related Fmri

INTRODUCTION: Since normal variations in fMRI responses are considerable across subjects, it is critical to understand and account for these intersubject variations, in order for fMRI to be possibly used as a personalized diagnostic tool for brain diseases. Previous studies have reported a few physiologic modulators that could explain the inter-subject variations and may potentially be used for...

متن کامل

Combined MEG and fMRI model

An integrated model for magnetoencephalography (MEG) and functional Magnetic Resonance Imaging (fMRI) is proposed. In the proposed model, MEG and fMRI outputs are related to the corresponding aspects of neural activities in a voxel. Post synaptic potentials (PSPs) and action potentials (APs) are two main signals generated by neural activities. In the model, both of MEG and fMRI are related to t...

متن کامل

Diazoxide, a KATP Channel Opener, Prevented Ethanol-Induced Gastric Ulceration in Rats

Ethanol-induced acute gastric ulceration (EIGU) is widely studied. ATP dependent potassium channel (KATP) modulators are thought to interfere with some physiologic functions of the stomach. We have studied the effects of different doses of KATP modulators (diazoxide as agonist and glibenclamide as antagonist) on EIGU in rats. Gastric lesions were quantified. Fasting blood glucose (FBS) levels w...

متن کامل

The Relationship Between M in “Calibrated fMRI” and the Physiologic Modulators of fMRI

The "calibrated fMRI" technique requires a hypercapnia calibration experiment in order to estimate the factor "M". It is desirable to be able to obtain the M value without the need of a gas challenge calibration. According to the analytical expression of M, it is a function of several baseline physiologic parameters, such as baseline venous oxygenation and CBF, both of which have recently been ...

متن کامل

Effect of Physiological noise on Thoraco-Lumbar spinal cord fMRI in 3T Magnetic field

Introduction: Functional MRI methods have been used to study sensorimotor processing in the brain and the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as signifi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Human brain mapping

دوره 34 9  شماره 

صفحات  -

تاریخ انتشار 2013