Relationship between left atrial appendage function and left atrial thrombus in patients with nonvalvular chronic atrial fibrillation and atrial flutter.

نویسندگان

  • Tatsuyoshi Narumiya
  • Tatsuo Sakamaki
  • Yuichi Sato
  • Katsuo Kanmatsuse
چکیده

The relationship between the left atrial appendage (LAA) function, as assessed by transesophageal echocardiography, and the incidence of left atrial thrombus was evaluated in 62 patients with nonvalvular chronic atrial fibrillation (AF; n=50) and atrial flutter (AFL; n=12). It was hypothesized that in both AF and AFL not only the LAA flow velocity (LAAFV), but also the frequency of the LAA movement (the LAA flow time, LAAFT) is a major contributing factor to thrombus formation. LAAFT was defined as the average duration of LAA flow with emptying and filling waves. The patients with AF were divided into 2 groups: lone AF (n=14) and non-lone AF (n=36). LAA thrombus was found in 6 patients with none-lone AF. LAAFV was lower and LAAFT was shorter in patients with thrombus as compared with patients without thrombus (12.0+/-2.2 cm/s vs 24.1+/-10.6 cm/s, 68.7+/-1.5 ms vs 72.9+/-3.3 ms, p<0.01, respectively). Patients with AFL had higher LAAFV and longer LAAFT than those with chronic AF. The present data suggest that, in addition to LAAFV, LAAFT characterized LAA function and might serve as a predictor of thrombus formation in chronic AF. With respect to LAA function, patients with lone AF or AFL are at low risk for thrombus formation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures

Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...

متن کامل

The value of diastolic function parameters in the prediction of left atrial appendage thrombus in patients with nonvalvular atrial fibrillation

BACKGROUND Left ventricular diastolic impairment and consequently elevated filling pressure may contribute to stasis leading to left atrial appendage thrombus (LAAT) in nonvalvular atrial fibrillation (AF). We investigated whether transthoracic echocardiographic parameters can predict LAAT independent of traditional clinical predictors. METHODS We conducted a retrospective cohort study of 297...

متن کامل

High plasma brain natriuretic polypeptide level as a marker of risk for thromboembolism in patients with nonvalvular atrial fibrillation.

BACKGROUND AND PURPOSE Assessment of left atrial appendage (LAA) function with transesophageal echocardiography is useful for detecting patients at high risk for thromboembolism as a result of atrial fibrillation (AF). A recent study reported that the atrium is the main source of brain natriuretic polypeptide (BNP) in AF patients without overt heart failure. The purpose of this study was to ass...

متن کامل

Left atrial appendage function in patients with atrial flutter.

OBJECTIVE To determine whether echocardiographic markers thromboembolic risk differ between patients with pure atrial flutter and patients with atrial flutter and intermittent atrial fibrillation. DESIGN Patients with atrial flutter were followed up prospectively for 12 months to identify intermittent atrial fibrillation. After the follow up period, transthoracic and multiplane transoesophage...

متن کامل

Echocardiographic assessment of the left atrial appendage.

The left atrial (LA) appendage is a common source of cardiac thrombus formation associated with systemic embolism. Transesophageal echocardiography allows a detailed evaluation of the structure and function of the appendage by two-dimensional imaging and Doppler interrogation of appendage flow. Specific flow patterns, reflecting appendage function, have been characterized for normal sinus rhyth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 67 1  شماره 

صفحات  -

تاریخ انتشار 2003