Determination of Circular Arc Length and Midpoint by Hough Transform

نویسندگان

  • Soo-Chang Pei
  • Ji-Hwei Horng
چکیده

We propose a method to detect circular arcs, including the determinations of their centers, radii, lengths, and midpoints. The center, radius of a circular arc can easily be determined using circular Hough transform. But, the determinations of the arc midpoint and length are more complicated. Theoretical analysis of the centroid of the near peak Hough transform data is presented. Then, the arc midpoint and length can be extracted from it.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Circular arc detection based on Hough transform

A new method is proposed to detect circular arcs. The detection of a circular arc includes the determination of its center, radius, length, and midpoint. The Hough transform is applied to detect circular arcs by using center and radius as parameters. A peak value in the parameter space of the Hough transform indicates the existence of a circular arc. The center and radius of the circular arc ar...

متن کامل

Iris localization by means of adaptive thresholding and Circular Hough Transform

In this paper, a new iris localization method for mobile devices is presented. Our system uses both intensity and saturation threshold on the captured eye images to determine iris boundary and sclera area, respectively. Estimated iris boundary pixels which have been placed outside the sclera will be removed. The remaining pixels are mainly the boundary of iris inside the sclera. Then, circular ...

متن کامل

Detection of Microaneurysms in Retinal Angiography Images Using the Circular Hough Transform

This paper presents an automated method for detecting microaneurysms in the retinal angiographic images by using image processing techniques. In the presented method, in order to fade or remove the pseudo images, first retinal images are pre-processed. Then microaneurysms are identified by circular Hough transform. In the existing methods of dete...

متن کامل

Detection of Microaneurysms in Retinal Angiography Images Using the Circular Hough Transform

This paper presents an automated method for detecting microaneurysms in the retinal angiographic images by using image processing techniques. In the presented method, in order to fade or remove the pseudo images, first retinal images are pre-processed. Then microaneurysms are identified by circular Hough transform. In the existing methods of dete...

متن کامل

A Novel Approach for Coin Identification using Eigenvalues of Covariance Matrix, Hough Transform and Raster Scan Algorithms

In this paper we present a new method for coin identification. The proposed method adopts a hybrid scheme using Eigenvalues of covariance matrix, Circular Hough Transform (CHT) and Bresenham’s circle algorithm. The statistical and geometrical properties of the small and large Eigenvalues of the covariance matrix of a set of edge pixels over a connected region of support are explored for the pur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1994