Three-dimensional fast-recovery fast spin-echo MRCP: comparison with two-dimensional single-shot fast spin-echo techniques.

نویسندگان

  • Aaron Sodickson
  • Koenraad J Mortele
  • Matthew A Barish
  • Kelly H Zou
  • Steven Thibodeau
  • Clare M C Tempany
چکیده

PURPOSE To retrospectively evaluate the technical quality of and the visibility of the biliary tree and pancreatic duct on magnetic resonance (MR) cholangiopancreatographic (MRCP) images obtained with a single-breath-hold three-dimensional (3D) fast-recovery fast spin-echo (FRFSE) sequence in comparison with conventional two-dimensional (2D) single-shot fast spin-echo (SSFSE) thin-section and thick-slab sequences. MATERIALS AND METHODS Institutional review board approval was obtained; informed consent was not required for this HIPAA-compliant study. MRCP was performed at 1.5 T in 53 consecutive patients (25 men and 28 women, aged 23-84 years). A single-breath-hold volume acquisition was performed by using the 3D FRFSE sequence and the conventional 2D SSFSE sequences. Two radiologists graded studies obtained with each sequence in a blinded fashion, and the paired Student t test was used to assess differences in technical quality, visibility of eight individual ductal segments of the biliary tree and pancreatic duct, and number of ductal segments visualized per patient. RESULTS Studies obtained with 3D FRFSE were of significantly higher technical quality than those obtained with thin-section 2D SSFSE (P < .02 for both readers). The 3D FRFSE maximum intensity projection reconstruction and 2D SSFSE thick-slab sequence proved statistically equivalent with regard to the overall visibility of the biliary tree and pancreatic duct and the number of ductal segments visualized per patient. In comparison with 2D SSFSE thin-section imaging, however, 3D FRFSE imaging produced an improved overall duct segment visibility grade of 0.45 on a three-point visibility scale (P < .001), with a corresponding average per-patient improvement of 1.9 out of eight possible fully visualized duct segments (P < .001). CONCLUSION The 3D FRFSE sequence shows promise for improved visibility of the pancreatic duct and biliary tree, compared with the conventional 2D SSFSE thin-section and thick-slab approach, while permitting the entire MRCP examination to be performed in a single breath hold.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Contrast-Enhanced Magnetic Resonance Cholangiography: Practical Tips and Clinical Indications for Biliary Disease Management

Since its introduction, MRCP has been improved over the years due to the introduction of several technical advances and innovations. It consists of a noninvasive method for biliary tree representation, based on heavily T2-weighted images. Conventionally, its protocol includes two-dimensional single-shot fast spin-echo images, acquired with thin sections or with multiple thick slabs. In recent y...

متن کامل

Half-fourier acquisition single-shot turbo spin-echo (HASTE) MR: comparison with fast spin-echo MR in diseases of the brain.

PURPOSE To compare an ultrafast T2-weighted (half-Fourier acquisition single-shot turbo spin-echo [HASTE]) pulse sequence with fast spin-echo T2-weighted sequences in MR imaging of brain lesions. METHODS Fast spin-echo and HASTE images of 34 consecutive patients over the age of 50 years or with suspected demyelinating disease were reviewed independently by two neuroradiologists for the number...

متن کامل

اندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی

Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiology

دوره 238 2  شماره 

صفحات  -

تاریخ انتشار 2006