Risks Related To Fluoroscopy Radiation Associated With Electrophysiology Procedures.

نویسندگان

  • Eugenio Picano
  • Emanuela Piccaluga
  • Renato Padovani
  • Claudio Antonio Traino
  • Maria Grazia Andreassi
  • Giulio Guagliumi
چکیده

The benefits of cardiac imaging are immense, and modern cardiac electrophysiology (EP) requires the extensive and versatile use of a variety of cardiac imaging and radiology-based techniques. In the cardiac electrophysiology lab, doses can range around a reference effective dose (ED) of 15 milliSievert corresponding to 750 chest x-rays for a cardiac radiofrequency ablation, ranging from less than 2 to > 60 mSv. The reference dose for a regular pacemaker or ICD implant is 4 mSv (range 1.4-17) and for a CRT implant is 22 mSv (range 2.2-95). Doses on the order of magnitude of 10-100 milliSievert (mSv) correspond to a low (albeit definite, not negligible) additional lifetime risk of fatal and non-fatal cancer from between 1 in 1000 (10 mSv) to 1 in 100 (100 mSv). The increasing use and complexity of cardiac electrophysiology techniques have not been matched by increasing awareness and knowledge by prescribers and practitioners. The protection of doctors is just as important as protection of patients. Most experienced (and most exposed) interventional cardiologists and electrophysiologists have an exposure per annum of around 5 mSv, two to three times higher than diagnostic radiologists, with a typical cumulative lifetime attributable risk on the order of magnitude of 1 cancer (fatal and non-fatal) per 100 exposed subjects. Operator dose per procedure correlates somewhat with the patient dose, but may be typically 1000 times lower depending upon the shielding employed (one unit of incidence scatter dose for the operator when 1000 units of incident dose are given to the patient). However, adequate radiation protection training and diligent protection can reduce this radiation exposure by 90%. The priority given to radioprotection in every cardiology department is an effective strategy for primary prevention of cancer, a strong indicator of the quality of the cardiology division, and the most effective shielding for enhancing the safety of patients, doctors, and staff.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...

متن کامل

Safety and Feasibility of a Minimally Fluoroscopic Approach for Ventricular Tachycardia Ablation in Patients With Structural Heart Disease: Influence of the Ventricular Tachycardia Substrate.

BACKGROUND We sought to evaluate the safety and feasibility of a minimally fluoroscopic approach using the CARTOUNIVU module during scar-related ventricular tachycardia (VT) ablation. METHODS AND RESULTS Consecutive patients with structural heart disease undergoing VT ablation using the CARTOUNIVU module were prospectively included and classified depending on their VT substrate: (1) ischemic ...

متن کامل

Radiation Dose and Cancer Risk of Cardiac Electrophysiology Procedures

Electrophysiology study (EPS) and radiofrequency catheter ablation (RFCA) are widely used for the diagnosis and treatment of cardiac arrhythmias. EPS and RFCA are very complicated procedures, requiring extended periods of time and advanced technologies that vary according to the disease of the patients. Fluoroscopy is used during EPS and RFCA to guide the catheter through the vessels while view...

متن کامل

Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz

Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...

متن کامل

Evaluation of Patient's Dose and Estimate of Cancer Risk in Electrophysiology Studies and Ablation in Cath Lab Center of Afshar Hospital, Yazd, Iran

Introduction: Today electrophysiology studies and ablation have been developed due to increasing arrhythmias disorder of heart. In these diagnostic – treatments methods, the use of fluoroscopy can be causes patient radiation dose, therefore evaluation of patient's absorbed dose is necessary to protection of the radiation. The aim of this study was to evaluate the absorbed dose in patients under...

متن کامل

Use of fluoroscopy in clinical electrophysiology in Europe: results of the European Heart Rhythm Association Survey.

Despite the advent of non-fluoroscopic technologies, fluoroscopy remains the cornerstone of imaging in most interventional electrophysiological procedures, from diagnostic studies to ablation interventions and device implantation. The purpose of the European Heart Rhythm Association survey was to provide an insight into regulatory policies and physicians' clinical practice when using fluoroscop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of atrial fibrillation

دوره 7 2  شماره 

صفحات  -

تاریخ انتشار 2014