Gadolinium as an alternative contrast agent for diagnostic and interventional angiographic procedures in patients with impaired renal function.
نویسندگان
چکیده
BACKGROUND The study was designed to investigate the safety and feasibility of gadopentetate dimeglumine, a gadolinium-based contrast medium, as an alternative angiographic contrast agent in patients with impaired renal function and high risk for iodinated contrast-induced nephropathy. METHODS Gadopentetate dimeglumine was used as the radiographic contrast agent in 32 diagnostic or interventional angiographic procedures in 29 patients (59% diabetics) with severe renal insufficiency (average serum creatinine of 3.6+/-1.4 mg/dl). The average dose of gadopentetate dimeglumine was 0.34+/-0.06 mmol/kg body weight. Gadopentetate dimeglumine was used either alone (n=20) or in conjunction with carbon dioxide (n=12). RESULTS Thirty-two angiographic procedures (24 diagnostic angiographies and 8 interventional procedures) were performed in 29 patients. For diagnostic purposes, eleven selective renal arteriographies, six angiographies of the iliac arteries and lower extremities, and seven venous angiographies of the upper extremity and central veins were performed. Interventional procedures consisted of two percutaneous transluminal renal angioplasties with stenting, four percutaneous peripheral vascular interventions, and two balloon angioplasties of a dialysis fistula. None of the patients, except one, had evidence of post-procedure contrast material-induced renal failure (increase in serum creatinine >0.5 mg/dl within 72 h) or other complications. This patient had a clinically important increase in serum creatinine level after percutaneous transluminal renal angioplasty and stenting, probably due to cholesterol embolism. Gadopentetate dimeglumine had sufficient radiographic density to allow adequate diagnostic visualization with digital subtraction equipment in all cases. CONCLUSIONS Gadopentetate dimeglumine is an alternative and safe radiographic contrast agent for angiography and interventional procedures in patients with severe pre-existing renal impairment. In this population with high risk for contrast-induced acute renal failure, it is obviously less nephrotoxic than iodinated contrast media.
منابع مشابه
Nephrotoxicity of iodixanol versus iopamidol in patients with chronic kidney disease and diabetes mellitus undergoing coronary angiographic procedures.
BACKGROUND The choice of radiographic contrast media for use in patients at increased risk of contrast-induced nephropathy (CIN) is of ongoing interest. METHODS The current study is a prospective, multicenter, randomized, double-blind design comparing the renal effects of the non-ionic, iso-osmolal agent, iodixanol, versus the non-ionic, low-osmolal agent, iopamidol, in 526 subjects with impa...
متن کاملPERIPHERAL VASCULAR DISEASE Interventional Rounds Does Gadolinium-Based Angiography Protect Against Contrast-Induced Nephropathy?: A Systematic Review of the Literature
We evaluated the incidence of contrast-induced nephropathy (CIN) in patients exposed to gadolinium for diagnostic or therapeutic procedures. Background: CIN with iodinated contrast agents is a leading cause of acute renal failure. Gadolinium is often used as an alternative to iodinated contrast in patients at increased risk of CIN. The safety of gadolinium in patients at increased risk of CIN h...
متن کاملGadolinium-Diethylenetriaminepenta-Acetic acid Conjugated with Monoclonal Antibody C595 as New Magnetic Resonance Imaging Contrast Agents for Breast Cancer (MCF-7) Detection
Background: The monoclonal antibody, C595, against breast cancer cell line was conjugated with cyclic anhydride gadolinium-diethylenetriaminepenta-acetic acid (Gd-cDTPAa) to produce Gd-DTPA-C595 and used as specific breast cancer cell line (MCF-7) contrast agents in magnetic resonance imaging (MRI). Methods: After incubation of breast cancer cell line (MCF-7), with different contrast agents (G...
متن کاملAudit of diagnostic and interventional craniocervical catheter angiographic procedures at the Singapore General Hospital.
INTRODUCTION Catheter angiography is an established imaging modality of evaluating cerebral and head and neck vascular diseases. It is, however, an invasive procedure with a small risk of complications. The aim of our study was to evaluate the prevalence of peri-procedural complications in a local hospital setting. MATERIALS AND METHODS A total of 88 patients underwent diagnostic and interven...
متن کاملGadolinium leakage into subarachnoid space and cystic metastases.
Subarachnoid space (SAS) and cystic metastatic lesions of brain parenchyma appear hypointense on fluid-attenuated inversion-recovery (FLAIR) and T1-weighted magnetic resonance imaging (MRI) unless there is a hemorrhage or elevated protein content. Otherwise, delayed enhancement and accumulation of contrast media in SAS or cyst of metastases should be considered. We present hyperintense SAS and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 17 5 شماره
صفحات -
تاریخ انتشار 2002