The Penumbra System: a mechanical device for the treatment of acute stroke due to thromboembolism.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Data from recent reports have indicated that mechanical thrombectomy may have potential as a treatment for acute ischemic stroke. The purpose of this study was to assess the safety and performance of the Penumbra System (PS): a novel mechanical device designed to reduce clot burden in acute stroke due to large-vessel occlusive disease. MATERIALS AND METHODS A prospective, single arm, independently monitored and core laboratory adjudicated trial enrolled subjects with an acute neurologic deficit consistent with acute stroke, presenting within 8 hours of symptom onset and an angiographically verified occlusion (Thrombolysis in Myocardial Infarction [TIMI] grade 0 or 1) of a treatable intracranial vessel. The primary end point was revascularization of the target vessel to TIMI grade 2 or 3. Secondary end points were the proportion of subjects who achieved a modified Rankin Scale (mRS) score of 2 or less or a 4-point improvement on the National Institutes of Health Stroke Scale (NIHSS) score at 30-day follow-up, as well as all-cause mortality. RESULTS Twenty-three subjects were enrolled, and 21 target vessels were treated in 20 subjects by the PS. At baseline, mean age was 60 years, mean mRS score was 4.6, and mean NIHSS score was 21. Postprocedure, all 21 of the treated vessels (100%) were successfully revascularized by the PS to TIMI 2 or 3. At 30-day follow-up, 9 subjects (45%) had a 4-point or more NIHSS improvement or an mRS of 2 or less. The all-cause mortality rate was 45% (9 of 20), which is lower than expected in this severe stroke cohort, where 70% of the subjects at baseline had either an NIHSS score of more than 20 or a basilar occlusion. CONCLUSION Thus, early clinical experience suggests that the PS allows revascularization in certain subjects experiencing acute ischemic stroke.
منابع مشابه
Investigation of physical penumbra definition in treatment planning
Background: Due to the small size of the beamlets in IMRT (intensity modulated radiotherapy), physical penumbra is one of the important dosimetric parameters and small changes in the penumbra have a notable impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating...
متن کاملThe Penumbra System for the Treatment of Acute Ischemic Stroke: Report of Two Cases.
Mortality associated with the occlusion of large vessels in acute ischemic stroke is particularly high despite best available medical therapy. Early and safe revascularization of the primary occlusion is correlated with good clinical result. We report two patients with acute ischemic stroke in whom the mechanical device Penumbra System was used for thrombolysis and embolectomy. The Penumbra Sys...
متن کاملFEATURED TECHNOLOGY: INDIGO SYSTEm
Existing endovascular options for lower extremity and visceral arterial thromboembolism face the challenges of limited trackability, vessel injury, and incomplete revascularization. At the forefront of advances in catheter materials and technology, Penumbra, Inc. recently introduced the IndigoTM System for mechanical thrombectomy in the periphery. The Indigo System is designed to address the li...
متن کاملTreatment of Acute Cerebral Artery Occlusion Using the Penumbra System: Our Early Experience
Intravenous recombinant tissue-type plasminogen activator (rt-PA) therapy is highly recommended to patients who are diagnosed with ischemic stroke within 4.5 hours after the onset while mechanical clot retrieval can be attempted in patients who are not indicated for or cannot effectively receive intravenous rt-PA therapy. In this article, we report early treatment outcomes and discuss the usefu...
متن کاملInvestigation of physical penumbra definition in IMRT applications
Introduction: Because of small size of the beamlets in IMRT, physical penumbra is one of the important dosimetric parameters and small changes in the penumbra will have a great impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating the inconsi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 29 7 شماره
صفحات -
تاریخ انتشار 2008