Integration of motion correction and physiological noise regression in fMRI

نویسندگان

  • Tyler B. Jones
  • Peter A. Bandettini
  • Rasmus M. Birn
چکیده

Physiological fluctuations resulting from the heart beat and respiration are a dominant source of noise in fMRI, particularly at high field strengths. Commonly used physiological noise correction techniques, such as RETROspective Image CORrection (RETROICOR), rely critically on the timing of the image acquisition relative to the heart beat, but do not account for the effects of subject motion. Such motion affects the fluctuation amplitude, yet volume registration can distort the timing information. In this study, we aimed to systematically determine the optimal order of volume registration, slice-time correction and RETROICOR in their traditional forms. In addition, we evaluate the sensitivity of RETROICOR to timing errors introduced by the slice acquisition, and we develop a new method of accounting for timing errors introduced by volume registration into physiological correction (motion-modified RETROICOR). Both simulation and resting data indicate that the temporal standard deviation is reduced most by performing volume registration before RETROICOR and slice-time correction after RETROCIOR. While simulations indicate that physiological noise correction with regressors constructed on a slice-by-slice basis more accurately modeled physiological noise compared to using the same regressors for the entire volume, the difference between these regression techniques in subject data was minimal. The motion-modified RETROICOR showed marked improvement in simulations with varying amounts of subject motion, reducing the temporal standard deviation by up to 36% over the traditional RETROICOR. Though to a lesser degree than in simulation, the motion-modified RETROICOR performed better in nearly every voxel in the brain in both high- and low-resolution subject data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Physiological noise on Thoraco-Lumbar spinal cord fMRI in 3T Magnetic field

Introduction: Functional MRI methods have been used to study sensorimotor processing in the brain and the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as signifi...

متن کامل

Effect of Physiological Noise on Thoraco-lumbar Spinal Cord FMRI in 3T Magnetic Field

Introduction: Functional MRI methods have been used to study sensorimotor processing in the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from the physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as significant sources of noise, especi...

متن کامل

Functional connectivity in the rat at 11.7 T: Impact of physiological noise in resting state fMRI

Resting state functional MRI (rs-fMRI) of the brain has the potential to elicit networks of functional connectivity and to reveal changes thereof in animal models of neurological disorders. In the present study, we investigate the contribution of physiological noise and its impact on assessment of functional connectivity in rs-fMRI of medetomidine sedated, spontaneously breathing rats at ultrah...

متن کامل

EEG-assisted retrospective motion correction for fMRI: E-REMCOR

We propose a method for retrospective motion correction of fMRI data in simultaneous EEG-fMRI that employs the EEG array as a sensitive motion detector. EEG motion artifacts are used to generate motion regressors describing rotational head movements with millisecond temporal resolution. These regressors are utilized for slice-specific motion correction of unprocessed fMRI data. Performance of t...

متن کامل

Optimizing preprocessing and analysis pipelines for single-subject fMRI. I. Standard temporal motion and physiological noise correction methods.

Subject-specific artifacts caused by head motion and physiological noise are major confounds in BOLD fMRI analyses. However, there is little consensus on the optimal choice of data preprocessing steps to minimize these effects. To evaluate the effects of various preprocessing strategies, we present a framework which comprises a combination of (1) nonparametric testing including reproducibility ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NeuroImage

دوره 42 2  شماره 

صفحات  -

تاریخ انتشار 2008