Subxiphoid cross-sectional echocardiographic imaging of the "goose-neck" deformity in endocardial cushion defect.

نویسندگان

  • H Yoshida
  • T Funabashi
  • S Nakaya
  • T Maeda
  • N Taniguchi
چکیده

The cross-sectional echocardiographic demonstration of the "goose-neck" deformity is described in four patients with endocardial cushion defect. The diagnosis was confirmed in each patient by left ventricular angiocardiogram. The subxiphoid approach of cross-sectional echocardiography in diastole allowed visualization of an elongated, narrowed, and somewhat horizontally inclined configuration of the left ventricular outflow tract, which appeared almost identical to that obtained by angiocardiography. In systole, the right border of the left ventricle was composed of the cleft anterior mitral leaflet, the left-sided line of which was convex toward the left ventricular cavity. The mitral valvular echoes were thickened, jagged and irregular, which seemed to correspond to the scalloped appearance of the right border of the left ventricular silhouette in a systolic phase of the left ventricular angiocardiogram. There were no obvious differences between the goose-neck configuration of complete-type endocardial cushion defect and that of ostium primum atrial septal defect.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subxiphoid Cross-sectional Echocardiographic Imaging of the "Goose-neck" Deformity

The cross-sectional echocardiographic demonstration of the "goose-neck" deformity is described in four patients with endocardial cushion defect. The diagnosis was confirmed in each patient by left ventricular angiocardiogram. The subxiphoid approach of cross-sectional echocardiography in diastole allowed visualization of an elongated, narrowed, and somewhat horizontally inclined configuration o...

متن کامل

The "goose neck" of the endocardial cushion defect: anatomic basis.

The "goose necku deformity as seen in left ventriculogrruas in the endocardial cushion defect persists after surgical treatment in whkh the subaodc deficiency of the venMcular septum is built up with prosthetic material and the natural mitral valve is replaced by a prosthesis. Anatomic studies indicate that the diaphragmatic (inflow) aspect of the left ventricle and the venMcuhu septum are shor...

متن کامل

Echocardiographic features of endocardial cushion defects.

The echocardiographic features of endocardial cushion defects were defined in 28 patients. Two basic characteristics, common to both complete and incomplete forms of endocardial cushion defects, were found. First, the mitral valve excursion was not seen best in the usual location as defined by intraventricular landmarks. Secondly, the mitral valve echoes in cases where there are dense attachmen...

متن کامل

Tetralogy of Fallot associated with persistent common atrioventricular canal (endocardial cushion defect).

A clinicopathological analysis was made of I3 cases in which the anatomical characteristics of tetralogy of Fallot were associated either with the classicalfeatures of the complete type of persistent common atrioventricular canal (8 cases) or with a forme fruste of the latter (5 cases); that is, cleft tricuspid valve (4 cases) and isolated ostium primum (one). The ratio offemale to male was IO ...

متن کامل

Diagnosis of endocardial cushion defect with cross-sectional and M-mode scanning echocardiography. Differentiation from secundum atrial septal defect.

Twelve cases of endocardial cushion defect were studied before and after operation with ultrasono-cardiotomography (tomography) cross-sectional echocardiography, two-dimensional echocardiography, B-scan echocardiography) and M-mode scan along a horizontal section of the heart. For comparison, 20 healthy subjects, 18 cases of mitral valvular disease, 4 cases of congestive cardiomyopathy, 1 case ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 62 6  شماره 

صفحات  -