Evaluation of Intravenous Medication Errors with Smart Infusion Pumps in an Academic Medical Center
نویسندگان
چکیده
While some published research indicates a fairly high frequency of Intravenous (IV) medication errors associated with the use of smart infusion pumps, the generalizability of these results are uncertain. Additionally, the lack of a standardized methodology for measuring these errors is an issue. In this study we iteratively developed a web-based data collection tool to capture IV medication errors using a participatory design approach with interdisciplinary experts. Using the developed tool, a prevalence study was then conducted in an academic medical center. The results showed that the tool was easy to use and effectively captured all IV medication errors. Through the prevalence study, violation errors of hospital policy were found that could potentially place patients at risk, but no critical errors known to contribute to patient harm were noted.
منابع مشابه
Evaluation of Use of Electronic Patient Controlled Analgesia Pumps to Improve Patient Safety in an Academic Medical Center
Patient controlled analgesia (PCA) and Patient-controlled epidural analgesia (PCEA) pumps are methods of pain control with complex smart infusion devices and are widely used in hospitals. Smart PCA/PCEA pumps can be programmed with the dose and rate of medications within pre-set ranges. However, adverse effects have been reported associated with these pumps' use. In this paper, we describe a pr...
متن کاملInsights from the sharp end of intravenous medication errors: implications for infusion pump technology.
BACKGROUND Intravenous (IV) medication errors are a common type of error identified in hospitals and can lead to considerable harm. Over the past 20 years there have been several hundred FDA reported incidents involving IV pumps, many of which have led to patient deaths. OBJECTIVE To determine the actual types, frequency, and severity of medication errors associated with IV pumps. To evaluate...
متن کاملA controlled trial of smart infusion pumps to improve medication safety in critically ill patients.
OBJECTIVE Intravenous medications are vital during inpatient management. Errors associated with the administration of medications through intravenous infusion pumps to critically ill patients can result in adverse drug events. We sought to assess the impact of smart pumps with integrated decision support software on the incidence and nature of medication errors and adverse drug events. DESIGN...
متن کاملAn Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملBenefits and risks of using smart pumps to reduce medication error rates: a systematic review.
BACKGROUND Smart infusion pumps have been introduced to prevent medication errors and have been widely adopted nationally in the USA, though they are not always used in Europe or other regions. Despite widespread usage of smart pumps, intravenous medication errors have not been fully eliminated. OBJECTIVE Through a systematic review of recent studies and reports regarding smart pump implement...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AMIA ... Annual Symposium proceedings. AMIA Symposium
دوره 2013 شماره