Polarized light spatial frequency domain imaging for non-destructive quantification of soft tissue fibrous structures.

نویسندگان

  • Bin Yang
  • John Lesicko
  • Manu Sharma
  • Michael Hill
  • Michael S Sacks
  • James W Tunnell
چکیده

The measurement of soft tissue fiber orientation is fundamental to pathophysiology and biomechanical function in a multitude of biomedical applications. However, many existing techniques for quantifying fiber structure rely on transmitted light, limiting general applicability and often requiring tissue processing. Herein, we present a novel wide-field reflectance-based imaging modality, which combines polarized light imaging (PLI) and spatial frequency domain imaging (SFDI) to rapidly quantify preferred fiber orientation on soft collagenous tissues. PLI utilizes the polarization dependent scattering property of fibers to determine preferred fiber orientation; SFDI imaging at high spatial frequency is introduced to reject the highly diffuse photons and to control imaging depth. As a result, photons scattered from the superficial layer of a multi-layered sample are highlighted. Thus, fiber orientation quantification can be achieved for the superficial layer with optical sectioning. We demonstrated on aortic heart valve leaflet that, at spatial frequency of f = 1mm(-1) , the diffuse background can be effectively rejected and the imaging depth can be limited, thus improving quantification accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Attenuation of spatial aliasing in CMP domain by non-linear interpolation of seismic data along local slopes

Spatial aliasing is an unwanted side effect that produces artifacts during seismic data processing, imaging and interpolation. It is often caused by insufficient spatial sampling of seismic data and often happens in CMP (Common Mid-Point) gather. To tackle this artifact, several techniques have been developed in time-space domain as well as frequency domain such as frequency-wavenumber, frequen...

متن کامل

Band Structures for 2D Photonic Crystals in Presence of Nonlinear Kerr Effect ‎Calculated by Use of Nonlinear Finite Difference Time Domain (NFDTD) Method‎

We report the simulation results for impact of nonlinear Kerr effect on band structures of a ‎two dimensional photonic crystal (2D-PhC) with no defect, a PhC based W1-waveguide ‎‎(W1W), and also Coupled-Cavity Waveguides (CCWs). All PhC structres are assumed to a ‎square lattice of constant a made of GaAs rods of radius r=0.2a, in an air background. The ‎numerical simulation was performed using...

متن کامل

A Survey Of Soft Tissue Tumor-Like Lesions Of Oral Cavity: A Clinicopathological Study

  Background and Objective: Different mechanisms may lead to the development of soft tissue tumor-like lesions in the oral cavity. Many of these lesions can be identified as specific entities on the basis of their histopathological features and are divided into fibrous, vascular, and giant cell types. The purpose of this study was to establish the relative prevalence of the different histopath...

متن کامل

The Effect of Polarized Laser Radiation on Viscoelastic Properties of Soft Tissue

Background: Laser-tissue interaction on low-level laser therapy (LLLT) has widespread medical applications (e.g., improved wound healing). The tensile strength of radiated tissue by LLLT is known to be increased mainly because of cross collagen bands developed after radiation.Objective: In this work, we studied the instantaneous effect of radiation of polarized laser beam on the viscoelastic ti...

متن کامل

Determination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera

Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution.  The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical optics express

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2015