Electrocardiogram artefacts caused by an abdominal electrostimulator.
نویسندگان
چکیده
A 74-year-old woman presented to hospital with dyspnoea of sudden onset. She was in cardiogenic shock, with blood pressure of 90/50 mmHg, and pulse rate of 115 bpm. The electrocardio-gram (ECG) was difficult to interpret because of severe, persistent and inexplicable artefacts (Box 1A). Chest x-ray showed acute pulmonary oedema thought secondary to left ventricular failure. Echocardiography showed a left ventricular ejection fraction of 40% and anterior akinesia. Coronary angiography confirmed a proximal occlusion of the left anterior descending coronary artery, which was successfully treated by direct angioplasty and stenting. Review of the patient' s previous medical records revealed, on a thoracoabdominal image derived from computed tomography data, a foreign body in the central abdominal region (Box 2). Questioning of the patient after the angioplasty revealed that this was an electrostimulator (Itrel II, Medtronic, Minneapolis, USA) implanted a few years earlier as part of a dynamic graciloplasty to treat faecal incontinence. An ECG performed 12 hours after the angioplasty with the device deactivated (by the patient' s control programmer) produced an ECG tracing free of artefacts (Box 1B). Persistent and inexplicable ECG artefacts should raise the suspicion of interference from a device generating high frequency electrical impulses. Such devices may include minute ventilation rate-responsive pacemakers 1 and central or transcutaneous neuro-stimulators (eg, deep brain neurostimulators used in Parkinson' s disease, 2 and spinal neurostimulators used in chronic back pain 3). Occasionally, when the vector of impulses is perpendicular to an ECG lead, the tracing from that lead may be free of artefacts (eg, Box 1A, lead I). Intrathoracic devices are usually discovered on physical examination or standard chest x-ray, but devices in other parts of the body may not be obvious. In dynamic graciloplasty to treat anal incontinence, the gracilis muscle is transposed around the anal canal and electronically stimulated by a device placed in a subcutaneous pocket in the abdominal wall. 4 In our case, this device led to ECG artefacts potentially interfering with the ability to diagnose the acute myocardial infarction. Implanted electrostimulation devices are being used increasingly in medicine and should be considered as a possible source of ECG artefacts, especially by frontline clinicians confronted daily with such life-threatening conditions as acute coronary syndromes. 1 Southorn PA, Kamath GS, Vasdev GM, Hayes DL. Monitoring equipment induced tachycardia in patients with minute ventilation rate-responsive pacemakers. 1 Electrocardiograms in a patient with an electrostimulation device A. On presentation, showing …
منابع مشابه
دردهای جلوی قلبی در اثر بیماریهای احشاء همراه با تغییرات (E.K.G) WEDDESKY PHENOMENON گزارش شش مورد
SUMMARY REPORT OF 6 CASES WITH ELECTROCARDIOGRAPHIC ST- T CHANGES DURING CHES PAIN INDUCED BY UPPER ABDOMINAL DISORDERS. DR. AUNOSI BAR/ICAR ; CHIEF CARDIOLOGIST GIULAN UNIVERSITY OF MEDICAL SCIENCES RASHT. IRAN 6 Cases of precordial pain caused by upper Abdominal Problems including gall stones, Acute cholecystitis , Acute pancreatitiy and Duodenal ulcer are being reported in this article. ...
متن کاملINTELLIGENT TECHNIQUE OF CANCELING MATERNAL ECG IN FECG EXTRACTION
In this paper, we propose a technique of artificial intelligence called adaptive neuro fuzzy inference system (ANFIS) for canceling maternal electrocardiogram (MECG) in fetal electrocardiogram extraction (FECG).This technique is used to estimate the MECG present in the abdominal signal of a pregnant woman. The FECG is then extracted by subtracting the estimated MECG from the abdominal signal. P...
متن کاملMulti-step Independent Component Analysis for Removing Cardiac Artefacts from Back SEMG Signals
The Electromyogram (EMG) signals recorded from the back muscles often contain large electrocardiogram (ECG) artefacts. For better interpretation of these SEMG signals, it is essential to remove ECG artefacts. This paper reports research conducted to address the problem of removing ECG artefacts from SEMG recordings using new approach of Independent Component Analysis (ICA) called Multi-step ICA...
متن کاملHemoperitoneum Caused by Placenta Percreta in the Third Trimester of Pregnancy
The placental adhesive disorders such as placenta accreta and placenta percreta are the rare causes of serious obstetric hemorrhages. They are associated with high maternal morbidity and mortality. Placenta percreta is usually diagnosed in the third trimester of pregnancy as a massive postpartum hemorrhage when an attempt to remove the placenta reveals lack of a cleavage plane. Here we report a...
متن کاملAn Exploratory Study of the Effective Mediating Artefacts in Listening through Systemic Theoretical Instruction (STI) among English as Foreign Language Learners
This research study investigated the development of listening proficiency level by the aid of different media- tional artifacts in Systemic Theoretical Instruction (STI). The study considered whether exposing learners to different types and various numbers of mediating artefacts would increase their awareness towards listen- ing concepts after two months, and consequently promote their listenin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Medical journal of Australia
دوره 181 8 شماره
صفحات -
تاریخ انتشار 2004