BACKGROUND Metabolomics LC-MS experiments yield large numbers of peaks, few of which can be identified by database matching. Many of the remaining peaks correspond to derivatives of identified peaks (e.g., isotope peaks, adducts, fragments and multiply charged molecules). In this article, we present a data-reduction approach that automatically identifies these derivative peaks. RESULTS Using data-driven clustering based on chromatographic peak shape correlation and intensity patterns across biological replicates, derivative peaks can be reliably identified. Using a test data set obtained from Leishmania donovani extracts, we achieved a 60% reduction of the number of peaks. After quality control filtering, almost 80% of the peaks could putatively be identified by database matching. CONCLUSION Automated peak filtering substantially speeds up the data-interpretation process.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving peak detection in high-resolution LC/MS metabolomics data using preexisting knowledge and machine learning approach

MOTIVATION Peak detection is a key step in the preprocessing of untargeted metabolomics data generated from high-resolution liquid chromatography-mass spectrometry (LC/MS). The common practice is to use filters with predetermined parameters to select peaks in the LC/MS profile. This rigid approach can cause suboptimal performance when the choice of peak model and parameters do not suit the data...

متن کامل

Post-acquisition filtering of salt cluster artefacts for LC-MS based human metabolomic studies

Liquid chromatography-high resolution mass spectrometry (LC-MS) has emerged as one of the most widely used platforms for untargeted metabolomics due to its unparalleled sensitivity and metabolite coverage. Despite its prevalence of use, the proportion of true metabolites identified in a given experiment compared to background contaminants and ionization-generated artefacts remains poorly unders...

متن کامل

Authenticity Assessment of Fruit Juices using LC-MS/MS and Metabolomic Data Processing

Liquid Chromatography coupled to tandem Mass Spectrometry (LC-MS/MS) with an AB SCIEX 4000 Q TRAP system was used for comprehensive fingerprinting of several fruit juices. Metabolomic data processing tools were used for authentication, i.e. classification of juices and adulteration detection. The developed statistical model was able to reliably detect 25% of orange juice adulteration with apple...

متن کامل

LC-MS and GC-MS based metabolomics platform for cancer research

We present here a LC-MS and GC-MS based analytical platform for the comprehensive analysis of cellular metabolites, including water-soluble metabolites, and waterinsoluble fatty acids, and phospholipids. The entire workflow consists of metabolic extraction, LC-MS and GC-MS runs, data analysis and interpretation. Standard operation procedures have been developed for the metabolite extraction fro...

متن کامل

Increasing the mass accuracy of high-resolution LC-MS data using background ions: a case study on the LTQ-Orbitrap.

With the advent of a new generation of high-resolution mass spectrometers, the fields of proteomics and metabolomics have gained powerful new tools. In this paper, we demonstrate a novel computational method that improves the mass accuracy of the LTQ-Orbitrap mass spectrometer from an initial +/- 1-2 ppm, obtained by the standard software, to an absolute median of 0.21 ppm (SD 0.21 ppm). With t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Bioanalysis

دوره 1 9  شماره 

صفحات  -

تاریخ انتشار 2009