RP-HPLC Method Development for Estimation of Sildenafil Citrate in Tablets and in Seminal Fluid
نویسندگان
چکیده
A RP HPLC method for estimation of sildenafil citrate (SC) in tablet dosage form and seminal fluid was developed and validated. Best resolution was obtained with column Waters Spherisorb® C18 bonded silica, (5 μm, 4.6 x 250 mm) at 230 nm with retention time of 5.01 min. The mobile phase used was TEA (0.2%) pH adjusted at 3 with OPA and ACN (60:40) with flow rate of 1.0 mL/min. The method for estimation of sildenafil citrate in tablet dosage form was found to be linear, accurate, precise, sensitive and selective. Whereas the bioanalytical estimation of SC in seminal fluid was found to be in the range of 100 ng/mL to 10μg/mL. Method was found to be highly sensitive as LOD and LOQ were found to 0.3 μg/ml and 0.9μg/ml. The repeatability and reproducibility were within the range i.e. less than 2%.The accuracy of the method was 99.3%. The percentage purity was calculated for market formulation was 102.8%. The internal standard used for bioanalytical methods was Diclofenac sodium. The drug was extracted from seminal fluid by protein precipitation using ACN as precipitating agent. The linearity range was from 100.0ng/mL to 2.0μg/mL. The LOD and LOQ were found to 0.03μg/mL and 0.1μg/mL. The repeatability and reproducibility were within the range i.e. % RSD less than 15%. The accuracy of the method was 90.36%.and the extraction efficiency was found to be 98.25%. The stability of drug was found to be within the range i.e. less the 15%.
منابع مشابه
Application of Narrow-Bore HPLC Columns in Rapid Determination of Sildenafil Citrate in Its Pharmaceutical Dosage Forms
A special type of silica-based columns has been recently introduced into the market which is called narrow-bore columns. They have lower internal volume than the standard high-performance liquid chromatography (HPLC) columns and thus reduce the solvent consumption by almost 80%. A simple, accurate and environmentally friendly reversed phase- HPLC (RP-HPLC method) which could be used in ...
متن کاملApplication of Narrow-Bore HPLC Columns in Rapid Determination of Sildenafil Citrate in Its Pharmaceutical Dosage Forms
A special type of silica-based columns has been recently introduced into the market which is called narrow-bore columns. They have lower internal volume than the standard high-performance liquid chromatography (HPLC) columns and thus reduce the solvent consumption by almost 80%. A simple, accurate and environmentally friendly reversed phase- HPLC (RP-HPLC method) which could be used in ...
متن کاملSimultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector
Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...
متن کاملSimultaneous RP-HPLC and UV Spectroscopic Method Development and Validation for Estimation of Ibandronate Sodium in Bulk and Pharmaceutical Dosage Form
The present study describes a simple, accurate, precise and cost effective UV-Vis Spectroscopic and RP-HPLC method for the estimation of Ibandronate sodium (IBN). The determination of Ibandronate sodium (IBN) was performed by both UV and RP-HPLC method using 215 nm as the determination wavelength. The drug was dissolved in NaOH solution (0.1N NaOH) for estimation in UV and in distilled water fo...
متن کاملDevelopment of an RP-HPLC-UV method for simultaneous detection of nimodipine and its metabolite in cerebrospinal fluid of rat
A rapid, simple and reproducible HPLC method was developed and validated for the analysis of nimodipine (NM) and/or its metabolite, oxidized nimodipine (OX–NM) in rat cerebrospinal fluid (CSF) and artificial CSF. The NM and OX–NM were eluted in less than 10 min with no interferences from the endogenous CSF peaks. Analysis was carried out on a Eurospher Performance (RP-C18, 250 × 4.6 mm) column ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012