Evaluation of Detection Characteristics for Scanning-Type Whole-Body Counter

نویسندگان

  • O. Kurihara
  • K. Takasaki
  • T. Momose
  • Y. Terakado
  • K. Takahashi
چکیده

As an alternative to the phantom used for calibrating whole-body counters, in this study the Monte Carlo simulation was used to evaluate peak efficiencies for a whole-body counter installed at the JNC, to examine the validity of using the simulation technique to calibrate the whole-body counter. Prior to simulating a phantom, the sensitive region of the crystal in the Ge detectors which are used with the whole-body counter, was evaluated by assuming dead layers in the simulation. The phantom was then simulated based on the determined configuration of the sensitive region. As a result, the calculated peak efficiencies were fairly consistent with the measured ones. For an entire body scanning measurement, the discrepancy between the measurement and the simulation was within 4% for peak energies ranging from 81.0 keV to 1460.8 keV. The simulation technique is therefore both effective and practical for situations that are difficult to be simulated by a phantom.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Whole Body Counter at Nagasaki University

A whole body counter was installed at Nagasaki University in 1968. Evaluation of the whole body counter was done by accumulated data during 15 years since its installation. The items used for the evaluation were the background radiation, the resolution and sensitivity of the measurement system. The characteristics of the apparatus has been stable for these years: The background counting rate wa...

متن کامل

- Fastscan - a Computerized, Anthropometrically Designed, High Throughput, Whole Body Counter for the Nuclear Industry

In the past ten years, the use of whole body counters in nuclear power plants has grown significantly. The average counting load is now 2000 5000 counts per year at a typical multi-unit station. This paper reports the results of our evaluation as to the desirable characteristics of a whole body counting system and the performance of the FASTSCAN counter. FASTSCAN is a linear geometry counter, d...

متن کامل

Comparison between early and delayed images of 67Ga scintigraphy for evaluation of recurrent lymphoma

Introduction: Despite widespread use of 67Gallium for lymphoma evaluation, timing of imaging after injection is a matter of controversy and to the extent of our knowledge no direct comparison has been made between early and delayed gallium images. We aimed to compare 24 and 48 hours post injection planar gallium imaging for evaluation of lymphoma recurrence. Methods: 255 pa...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

99mTc-DMSA (V) in detection of metastases of medullary thyroid carcinoma

Introduction: Medullary thyroid carcinoma (MTC) is a rare thyroid cancer secreting calcitonin (CT) which is the most sensitive and specific tumor marker for MTC. This type of thyroid cancer is able to metastasize to different body areas including regional lymph nodes, lungs, liver and bone. The aim of this study was to assess the sensitivity and specificity of [99mTc-DMSA (V)] whole body ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004