Measurement of bone metal contact (BMC) in retrieved maxillofacial osseointegrated implants.

نویسنده

  • G Granström
چکیده

Eighteen screw-shaped extraoral osseointegrated implants retrieved from 10 patients were analysed by microradiography. Retrieved implants were trephined with a border of surrounding bone, fixed, embedded in epon plastic, ground and processed for microradiography. The reasons for retrieval were unexplained pain (n = 4), inability to cope with the implants (n = 2), fracture of central screw (n = 2), skin penetration problems (n = 1) and trauma (n = 1). The study group comprised six males and four females with a mean age of 53.4 years (range: 9-81 years). All implants were clinically stable at the time of removal, and mean osseointegration time was 3 years (range: 1-5 years). Six implants were removed from the temporal bone, five from the frontal bone and seven from the maxilla. Bone metal contact was estimated to vary between 27% and 83%. Bone metal contact was lower in the frontal bone compared to the temporal bone or maxilla, and was further reduced after preoperative irradiation. Longer osseointegration time increased bone metal contact, as did increased age up to 60 years. It is concluded that extraoral osseointegrated implants in humans may integrate morphologically as well as clinically. By microradiography it was possible to define bone metal contact in the region of implant installation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Histologic evaluation of clinically successful osseointegrated implants retrieved from irradiated bone: a report of 2 patients.

The present study described the histologic findings of 2 implants and surrounding tissues retrieved from human irradiated bone. For the treatment of a malignant tumor, 50 Gy of irradiation after implant placement and 60 Gy of irradiation before implant placement were provided for patients 1 and 2, respectively. In patient 1, the implant and surrounding tissues were removed from the frontal bone...

متن کامل

Histologic and histomorphometric evaluation of peri-implant bone subjected to immediate loading: an experimental study with Macaca fascicularis.

PURPOSE Immediately loaded splinted implants can become osseointegrated when they are placed in the anterior part of the mandible. The concept of immediate loading has not been well examined in the posterior mandible. The aim of this study was to evaluate the hard tissue reactions around immediately loaded implants placed in the posterior mandible in the monkey model. MATERIALS AND METHODS Si...

متن کامل

Prosthetic treatment using an osseointegrated implant after secondary bone grafting of a residual alveolar cleft: a case report.

Conventionally, for dental reconstruction after bone grafting of the congenital residual alveolar cleft, a fixed prosthesis or removable partial denture is used. In this paper, residual alveolar cleft reconstruction with an osseointegrated implant following secondary bone grafting is described. The patient underwent secondary bone grafting of the residual alveolar cleft at the age of 18 years. ...

متن کامل

Mobility assessment with the Periotest system in relation to histologic findings of oral implants.

The relationship between mobility assessment with the Periotest system and histologic findings was evaluated for oral implants. Five screw-type implants of pure titanium were placed in the mandibles of four monkeys. Two implants in each monkey were occlusally overloaded. These implants were brushed once a week. Plaque was allowed to accumulate around unloaded implants with abutments in the same...

متن کامل

Impact of Dynamic and Static Load on Bone Around Implants: An Experimental Study in a Rat Model.

PURPOSE This study aimed to evaluate peri-implant bone reactions to dynamic and static loads in a rat model. MATERIALS AND METHODS Two cylindrical titanium implants were placed in the left tibia diaphysis of 39 rats, which were divided into three groups: static load for 4 weeks (S4), static load for 8 weeks (S8), and static load for 4 weeks followed by dynamic load for 4 weeks (S4D4). All imp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta oto-laryngologica. Supplementum

دوره 543  شماره 

صفحات  -

تاریخ انتشار 2000