In vitro validation of computational fluid dynamic simulation in human proximal airways with hyperpolarized 3He magnetic resonance phase-contrast velocimetry.

نویسندگان

  • Ludovic de Rochefort
  • Laurence Vial
  • Redouane Fodil
  • Xavier Maître
  • Bruno Louis
  • Daniel Isabey
  • Georges Caillibotte
  • Marc Thiriet
  • Jacques Bittoun
  • Emmanuel Durand
  • Gabriela Sbirlea-Apiou
چکیده

Computational fluid dynamics (CFD) and magnetic resonance (MR) gas velocimetry were concurrently performed to study airflow in the same model of human proximal airways. Realistic in vivo-based human airway geometry was segmented from thoracic computed tomography. The three-dimensional numerical description of the airways was used for both generation of a physical airway model using rapid prototyping and mesh generation for CFD simulations. Steady laminar inspiratory experiments (Reynolds number Re = 770) were performed and velocity maps down to the fourth airway generation were extracted from a new velocity mapping technique based on MR velocimetry using hyperpolarized (3)He gas. Full two-dimensional maps of the velocity vector were measured within a few seconds. Numerical simulations were carried out with the experimental flow conditions, and the two sets of data were compared between the two modalities. Flow distributions agreed within 3%. Main and secondary flow velocity intensities were similar, as were velocity convective patterns. This work demonstrates that experimental and numerical gas velocity data can be obtained and compared in the same complex airway geometry. Experiments validated the simulation platform that integrates patient-specific airway reconstruction process from in vivo thoracic scans and velocity field calculation with CFD, hence allowing the results of this numerical tool to be used with confidence in potential clinical applications for lung characterization. Finally, this combined numerical and experimental approach of flow assessment in realistic in vivo-based human airway geometries confirmed the strong dependence of airway flow patterns on local and global geometrical factors, which could contribute to gas mixing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Title in Vitro Validation of Computational Fluid Dynamics Simulation in Human Proximal Airways with Hyperpolarized 3 He Magnetic Resonance Phase-contrast Velocimetry

Computational fluid dynamics (CFD) and magnetic resonance (MR) gas velocimetry were concurrently performed to study airflow in the same model of human proximal airways. Realistic in vivo-based human airway geometry was segmented from thoracic computed tomography. The 3D numerical description of the airways was used both for generation of a physical airway model using rapid prototyping, and mesh...

متن کامل

In vitro validation of flow measurement with phase contrast MRI at 3 tesla using stereoscopic particle image velocimetry and stereoscopic particle image velocimetry-based computational fluid dynamics.

PURPOSE To validate conventional phase-contrast MRI (PC-MRI) measurements of steady and pulsatile flows through stenotic phantoms with various degrees of narrowing at Reynolds numbers mimicking flows in the human iliac artery using stereoscopic particle image velocimetry (SPIV) as gold standard. MATERIALS AND METHODS A series of detailed experiments are reported for validation of MR measureme...

متن کامل

Hyperpolarized 3He MR lung ventilation imaging in asthmatics: preliminary findings.

Asthma is a disease characterized by chronic inflammation and reversible obstruction of the small airways resulting in impaired pulmonary ventilation. Hyperpolarized 3He magnetic resonance (MR) lung imaging is a new technology that provides a detailed image of lung ventilation. Hyperpolarized 3He lung imaging was performed in 10 asthmatics and 10 healthy subjects. Seven asthmatics had ventilati...

متن کامل

A Numerical Simulation of Inspiratory Airflow in Human Airways during Exercise at Sea Level and at High Altitude

At high altitudes, the air pressure is much lower than it is at sea level and contains fewer oxygen molecules and less oxygen is taken in at each breath. This requires deeper and rapid breathing to get the same amount of oxygen into the blood stream compared to breathing in air at sea level. Exercises increase the oxygen demand and make breathing more difficult at high altitude. In this study, ...

متن کامل

Dynamic lung morphology of methacholine-induced heterogeneous bronchoconstriction.

Hyperpolarized (HP) 3helium (3He) dynamic MRI was used to investigate airway response in rats following intravenous (i.v.) bolus administration of a contractile agent, methacholine (MCh). The method provides direct visualization of the ventilated regions within the lung. Heterogeneous bronchoconstriction following the i.v. MCh injection was evident using this technique. These 3He dynamic lung i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of applied physiology

دوره 102 5  شماره 

صفحات  -

تاریخ انتشار 2007