PURPOSE To assess inter- and intra-observer errors in identifying the transepicondylar axis and Whiteside's line in a cadaveric model mimicking total knee arthroplasty. METHODS Four cadaveric knees with intact soft tissues were used. The knees were exposed anteriorly using the Insall approach, with the patella everted laterally. Three observers (2 surgeons and one trainee) took turns to identify the anatomic landmarks of the transepicondylar axis and Whiteside's line. Each observer repeated the process 20 times. Each identification was photographed and referenced with the true values obtained from the knees after they were stripped of all soft tissue. Inter- and intra-observer errors in the anatomic landmarks were compared. RESULTS Inter-observer error was significant with both the transepicondylar axis and Whiteside's line (p<0.001, one-way ANOVA). The intra-observer variation was greater for Whiteside's line than the transepicondylar axis (standard deviation, 4.2 vs 2.5 degrees). The maximum potential errors in the transepicondylar axis and Whiteside's line were 13 degrees and 24 degrees, respectively. CONCLUSION The accuracy of rotational alignment of the transepicondylar axis and Whiteside's line were operator-dependent, and their intra-operative reproducibility was low.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Femoral Component Rotation in Patellofemoral Joint Replacement: A Study Protocol for a Prospective Observational Study

Patellofemoral joint replacement is a successful treatment option for isolated patellofemoral osteoarthritis. The short and mid-term outcomes are related to malposition and unexplained pain. Whether external rotation of the femoral component in isolated patellofemoral joint replacement is required is unclear. The primary aim of this study is to determine the CT-measured femoral component rotati...

متن کامل

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian population).

BACKGROUND Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes' guiding distal femur rotational align...

متن کامل

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

Errors in the identification of the transepicondylar and anteroposterior axes of the distal femur in total knee replacement using minimally-invasive and conventional approaches: a cadaver study.

We have investigated the errors in the identification of the transepicondylar axis and the anteroposterior axis between a minimally-invasive and a conventional approach in four fresh-frozen cadaver knees. The errors in aligning the femoral prosthesis were compared with the reference transepicondylar axis as established by CT. The error in the identification of the transepicondylar axis was sign...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 16 3  شماره 

صفحات  -

تاریخ انتشار 2008