Towards 4D MVCBCT for lung tumor treatment
نویسنده
چکیده
Currently in our clinic, a mega-voltage cone beam computed tomography (MVCBCT) scan is performed before each treatment for patient localization. For nonsmall cell lung cancer (NSCLC) patients, a strain gauge is used as an external surrogate to indicate tumor motion in both the planning stage and the treatment stage. However, it is likely that the amplitude of tumor motion varies between treatment fractions without a corresponding change in the surrogate signal. Motion amplitude larger than what was planned may underdose the tumor and overexpose normal tissues. The overall objective of this project is to extend the capabilities of MVCBCT for respiratory motion management by taking advantage of 2D projection images. First, a new method was developed to detect ipsi-lateral hemi-diaphragm apex (IHDA) motion along superior-inferior (SI) direction in 3D. Then a respiratory correlated reconstruction method was implemented and verified. This method is able to create MVCBCT volume in the full exhale (FE) and the full inhale (FI) phases, respectively. The diaphragm to tumor motion ratio (DTMR) was derived by quantifying the absolute position of the tumor and IHDA in these two volumes. The DTMR and the extracted IHDA motion were further used to calibrate the strain gauge signal. Second, an organ motion detection approach was developed, in which the detection is converted into an optimal interrelated surface detection problem. The framework was first applied to tumor motion extraction, which enables accurate detection for large tumors (with a diameter not smaller than 1.9cm). The framework was then applied to lung motion extraction and the extracted lung motion model was used to create a series of displacement vector fields for a motion compensated (MC) reconstruction. The accuracy of both tumor extraction and the MC approach was validated, which shows their clinical feasibility.
منابع مشابه
Dynamic MLC Tracking Using 4D Lung Tumor Motion Modelling and EPID Feedback
Background: Respiratory motion causes thoracic movement and reduces targeting accuracy in radiotherapy. Objective: This study proposes an approach to generate a model to track lung tumor motion by controlling dynamic multi-leaf collimators. Material and Methods: All slices which contained tumor were contoured in the 4D-CT images for...
متن کامل3D Lung Tumor Motion Model Extraction from 2D Projection Images of Mega-voltage Cone Beam CT via Optimal Graph Search
In this paper, we propose a novel method to convert segmentation of objects with quasi-periodic motion in 2D rotational cone beam projection images into an optimal 3D multiple interrelated surface detection problem, which can be solved by a graph search framework. The method is tested on lung tumor segmentation in projection images of mega-voltage cone beam CT (MVCBCT). A 4D directed graph is c...
متن کاملFeasibility of using respiratory correlated mega voltage cone beam computed tomography to measure tumor motion
The purpose of this study was to test the feasibility of using respiratory correlated mega voltage cone-beam computed tomography (MVCBCT), taken during patient localization, to quantify the size and motion of lung tumors. An imaging phantom was constructed of a basswood frame embedded with six different-sized spherical pieces of paraffin wax. The Quasar respiratory motion phantom was programmed...
متن کاملDesign and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging
Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...
متن کاملDevelopment and Investigation of Intensity-modulated Radiation Therapy Treatment Planning for Four-dimensional Anatomy
Lung cancer is the leading cause of cancer-related deaths worldwide. Radiotherapy is one of the main treatment modalities of lung cancer. However, the achievable accuracy of radiotherapy treatment is limited for lung-based tumors due to respiratory motion. Four-dimensional (4D) radiotherapy explicitly accounts for anatomic motion by characterizing the motion, creating a treatment plan that acco...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016