Determination of 1-hydroxypyrene in human urine by acid hydrolysis coupled to solid-phase microextraction and semi-microcolumn liquid chromatography.

نویسنده

  • Hong-Wen Chen
چکیده

This study developed an acid hydrolysis coupled to a solid-phase microextraction method employing a semi-microcolumn liquid chromatography system, instead of enzyme hydrolysis with solid-phase extraction for the pretreatment of human urine samples, to detect urinary 1-hydroxypyrene (1-OHP). The complete separation and detection of urinary 1-hydroxyprene was performed using a high-performance liquid-chromatography fluorescence detection system with an analytical C(18) semi-microcolumn, 60% (v/v) aqueous acetonitrile elution, and a lambda(ex/em) = 348/388 nm pair detection wavelength. Calibration graphs were linear with very good correlation coefficients (r = 0.9997), and the detection limit was 1.0 ng/L. These important parameters for acid hydrolysis and solid-phase microextraction were investigated. The total recovery was above 83% in acid hydrolysis with solid-phase microextraction. The proposed method provided a relatively simple, convenient, and practical procedure to determine the level of urinary 1-hydroxypyrene in biological samples, and was successfully applied to detect the urine of students.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection

A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...

متن کامل

Development of a Simple and Efficient Method for Preconcentration and Determination of Trace Levels of Fexofenadine in Plasma and Urine Samples

A simple, inexpensive and sensitive three-phase hollow fiber liquid-phase microextraction (HFLPME) coupled with high performance liquid chromatography (HPLC) with UV detection was successfully developed for determination of trace level of an anti-Histamine drug, fexofenadine, in human plasma and urine. The analyte was extracted into n-octanol that was immobilized in the wall of a porous hollow ...

متن کامل

Solid Phase Extraction for 1-Hydroxypyrene as a Biomarker of Occupational Exposure to PAHs Prior to High Performance Liquid Chromatography

Urinary 1-hydroxypyrene is frequently used as a major metabolite and biological indicator of the overall exposure to polycyclic aromatic hydrocarbons. In this study, solid phase extraction was appropriately conditioned with regard to sample pH, sample concentration, loading flow rate, elution solvent, washing solvent, sample volume and sorbent mass. Octadecyl silica cartridge (C<su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 23 10  شماره 

صفحات  -

تاریخ انتشار 2007