Bending characteristics of polymethylmethacrylate columns, connecting bars of carbon fiber, titanium, and stainless steel used in external skeletal fixation and an acrylic interface.

نویسندگان

  • Pierre M Amsellem
  • Erick L Egger
  • Daniel L Wilson
چکیده

OBJECTIVE To (1) mechanically evaluate polymethylmethacrylate (PMMA) columns of various sizes and compare them to connecting bar materials (carbon fiber composite, titanium, stainless steel) and (2) compare the properties of an intact PMMA column to those of an acrylic interface. STUDY DESIGN Experimental mechanical study. SAMPLE POPULATION Experiment 1: 6 groups of 6 specimens each; experiment 2: 2 groups of 12 specimens each. METHODS All specimens were tested in 3-point bending. Stiffness, yield strength, and ultimate strength values were calculated for each specimen. RESULTS PMMA 1 columns (23.25 mm) compared favorably to titanium or stainless-steel bars. PMMA 3 columns (30.15 mm) and carbon fiber bars had similar yield strength but PMMA 3 columns were less stiff than carbon fiber bars. PMMA 3 columns had lower bending modulus and a higher variability in their mechanical properties than PMMA 1 or PMMA 2 (25.64 mm) columns. Acrylic interface specimens were less strong but as stiff as intact specimens. CONCLUSION An acrylic interface was easily created and had acceptable biomechanical characteristics. CLINICAL RELEVANCE PMMA 2 and PMMA 3 columns are not recommended for clinical use at this time. Further tests are needed to analyze an acrylic patch in a more clinically relevant loading model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical comparison between bicortical pin and monocortical screw/polymethylmethacrylate constructs in the cadaveric canine cervical vertebral column.

OBJECTIVE To compare biomechanical stiffness of cadaveric canine cervical spine constructs stabilized with bicortical stainless steel pins and polymethylmethacrylate (PMMA), monocortical stainless steel screws with PMMA, or monocortical titanium screws with PMMA. STUDY DESIGN Biomechanical cadaver study. ANIMALS Eighteen canine cervical vertebral columns (C2-C7) were collected from skeletal...

متن کامل

Evaluation of the Melted Zone Microstructure in the Interface of the Dissimilar Weld between A335 Low Alloy Steel and ER309L Filler Metal by Gas Tungsten Arc Welding

In the present study, the microstructure and mechanical properties of the dissimilar welding between ASTM A335 low alloy steel and ER309L austenitic stainless steel were investigated using the gas tungsten arc welding process. The welding of dissimilar materials between ASTM A335 low alloy steel and ER309L austenitic stainless steel was found to have a significant effect on the microstructure w...

متن کامل

Effect of the TLP process parameters on microstructure, mechanical properties and corrosion resistance of 316L stainless steel to pure commercial titanium joint with pure copper interface

In this research, effect of time and temperature of TLP process on the microstructure, mechanical properties and corrosion resistance of CP-Ti to 316L stainless steel joint evaluated. For this purpose pure copper foil with 100 µm thickness was used as interlayer and joining process carried out at 950˚C, 1000˚C and 1050˚C and for 90, 120 and 150 minutes. After the joining process, shear and micr...

متن کامل

Flexural Strengthening of Deficient Reinforced Concrete Beams with Post-Tensioned Carbon Composites using Finite Element Modelling

The application of external post-tensioned steel bars as an effective way to strengthen an existing bridge has been so far used in many different countries. In recent decades, however, they have been replaced by bars made from Carbon Fiber Reinforced Polymer (CFRP), as a material with high tensile strength and corrosion resistance, to address several concerns with steel bars such as their appli...

متن کامل

Fracture resistance of abutment screws made of titanium, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone.

Fractured abutment screws may be replaced; however, sometimes, the screw cannot be removed and the entire implant must be surgically removed and replaced. The aim of this study was to compare the fracture resistance of abutment retention screws made of titanium, polyetheretherketone (PEEK) and 30% carbon fiber-reinforced PEEK, using an external hexagonal implant/UCLA-type abutment interface ass...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Veterinary surgery : VS

دوره 39 5  شماره 

صفحات  -

تاریخ انتشار 2010