Effect of non-invasive calibration of radial waveforms on error in transfer-function-derived central aortic waveform characteristics.

نویسندگان

  • Sarah A Hope
  • Ian T Meredith
  • James D Cameron
چکیده

Transfer function techniques are increasingly used for non-invasive estimation of central aortic waveform characteristics. Non-invasive radial waveforms must be calibrated for this purpose. Most validation studies have used invasive pressures for calibration, with little data on the impact of non-invasive calibration on transfer-function-derived aortic waveform characteristics. In the present study, simultaneous invasive central aortic (Millar Mikro-tip catheter transducer) and non-invasive radial (Millar Mikro-tip tonometer) pressure waveforms and non-invasive brachial pressures (Dinamap) were measured in 42 subjects. In this cohort, radial waveforms were calibrated to both invasive and non-invasive mean and diastolic pressures. From each of these, central waveforms were reconstructed using a generalized transfer function obtained by us from a previous cohort [Hope, Tay, Meredith and Cameron (2002) Am. J. Physiol. Heart Circ. Physiol. 283, H1150-H1156]. Waveforms were analysed for parameters of potential clinical interest. For calibrated radial and reconstructed central waveforms, different methods of calibration were associated with differences in pressure (P<0.001), but not time parameters or augmentation index. Whereas invasive calibration resulted in little error in transfer function estimation of central systolic pressure (difference -1+/-8 mmHg; P=not significant), non-invasive calibration resulted in significant underestimation (7+/-12 mmHg; P<0.001). Errors in estimated aortic parameters differed with non-invasively calibrated untransformed radial and transfer-function-derived aortic waveforms (all P<0.01), with smaller absolute errors with untransformed radial waveforms for most pressure parameters [systolic pressure, 5+/-16 and 7+/-12 mmHg; pulse pressure, 0+/-16 and 4+/-12 mmHg (radial and derived aortic respectively)]. When only non-invasive pressures are accessible, analysis of untransformed radial waveforms apparently produces smaller errors in the estimation of central aortic systolic pressure, and other waveform parameters, than using a generalized transfer function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of arterial transfer functions for the derivation of central aortic waveform characteristics in subjects with type 2 diabetes and cardiovascular disease.

OBJECTIVE Optimal blood pressure control in subjects with diabetes reduces cardiovascular complications. There is theoretical benefit in the assessment of central aortic waveforms including the augmentation index, which is taken as a putative index of stiffness. Transfer functions may be used to reconstruct aortic from radial pressure waveforms; however, a single generalized transfer function m...

متن کامل

Central Blood Pressure/Aortic Stiffness Validation of a Brachial Cuff-Based Method for Estimating Central Systolic Blood Pressure

The prognostic value of central systolic blood pressure has been established recently. At present, its noninvasive assessment is limited by the need of dedicated equipment and trained operators. Moreover, ambulatory and home blood pressure monitoring of central pressures are not feasible. An algorithm enabling conventional automated oscillometric blood pressure monitors to assess central systol...

متن کامل

Is there any advantage to using an arterial transfer function?

(typed double-spaced) in length and may be subject to editing or abridgment. To the Editor: We read with interest the paper by Millasseau et al, 1 which raises the question of whether the application of an arterial transfer function to noninvasively acquired radial artery pressure waveform data is necessary for the estimation of central aortic waveform characteristics. Although the conclusion t...

متن کامل

Comparison of generalized and gender-specific transfer functions for the derivation of aortic waveforms.

Arterial transfer functions have been promoted for the derivation of central aortic waveform characteristics not usually accessible noninvasively, but possibly of prognostic significance. The utility of generalized rather than gender-specific transfer functions has not been assessed. Invasive central aortic and noninvasive radial (Millar Mikro-tip tonometer) blood pressure waveforms were record...

متن کامل

Impact of radial artery pressure waveform calibration on estimated central pressure using a transfer function approach.

Impact of Radial Artery Pressure Waveform Calibration on Estimated Central Pressure Using a Transfer Function Approach To the Editor: It is with great interest that we have read the excellent work of McEniery et al1 on the variability of the relation between central and brachial pulse pressure (pressure amplification), assessed in 10 000 subjects. We were, however, a little surprised about the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science

دوره 107 2  شماره 

صفحات  -

تاریخ انتشار 2004