Recommendations of the American Association of Physicists in Medicine on 103Pd interstitial source calibration and dosimetry: implications for dose specification and prescription.

نویسندگان

  • J F Williamson
  • B M Coursey
  • L A DeWerd
  • W F Hanson
  • R Nath
  • M J Rivard
  • G Ibbott
چکیده

The National Institute of Standards and Technology (NIST) introduced a national standard for air kerma strength of the ThreaSeed Model 200 103Pd source (the only 103Pd seed available until 1999) in early 1999. Correct implementation of the NIST-99 standard requires the use of dose rate constants normalized to this same standard. Prior to the availability of this standard, the vendor's calibration procedure consisted of intercomparing Model 200 seeds with a 109Cd source with a NIST-traceable activity calibration. The AAPM undertook a comprehensive review of 103Pd source dosimetry including (i) comparison of the vendor and NIST-99 calibration standards; (ii) comparison of original Task Group 43 dosimetry parameters with more recent studies; (iii) evaluation of the vendor's calibration history; and (iv) evaluation of administered-to-prescribed dose ratios from the introduction of 103Pd sources in 1987 to the present. This review indicates that for a prescribed dose of 115 Gy, the administered doses were (a) 124 Gy for the period 1988-1997 and (b) 135 Gy for the period 1997-1999. The AAPM recommends that the following three steps should be undertaken concurrently to implement correctly the 1999 dosimetry data and NIST-99 standard for 103Pd source: (1) the vendor should provide calibrations in terms of air kerma strength traceable to NIST-99 standard, (2) the medical physicist should update the treatment planning system with properly normalized (to NIST-99) dosimetry parameters for the selected 103Pd source model, and (3) the radiation oncologist in collaboration with the medical physicist should decide which clinical experience they wish to duplicate; the one prior to 1997 or the one from 1997 to 1999. If the intent is to duplicate the experience prior to 1997, which is backed by the long-term follow-up and published outcome studies, then the prior prescriptions of 115 Gy should be replaced by 124 Gy to duplicate that experience.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of TG-43 Dosimetric Parameters for Photon Emitting Brachytherapy Sources

Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...

متن کامل

Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds

Background: A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC), is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet.Objective: The present study aims to modify source strength for different configurations of 125I and 103...

متن کامل

Recommendations of the American Association of Physicists in Medicine

In March 2004, the recommendations of the American Association of Physicists in Medicine sAAPMd on the interstitial brachytherapy dosimetry using I and Pd were reported in Medical Physics fTG-43 Update: Rivard et al., 31, 633–674 s2004dg. These recommendations include some minor changes in the dose-calculation formalism and a major update of the dosimetry parameters for eight widely used inters...

متن کامل

Dosimetric characterization of a high dose rate 192I source for brachytherapy application using Monte Carlo simulation and benchmarking with thermoluminescent dosimetry

Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...

متن کامل

Guidance to users of Nycomed Amersham and North American Scientific, Inc., I-125 interstitial sources: dosimetry and calibration changes: recommendations of the American Association of Physicists in Medicine Radiation Therapy Committee Ad Hoc Subcommittee on Low-Energy Seed Dosimetry.

Dose calculations to patients undergoing implantation of 125I interstitial brachytherapy sources are affected by two recent changes in low-energy seed dosimetry: (a) implantation of a new primary air-kerma strength standard at the National Institute of Standards and Technology (NIST) on 1 January 1999 and (b) publication of revised dose-rate distributions in AAPM's Task Group 43 Report. The gui...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 2000