Effect of parameter variations on the hemodynamic response under rotary blood pump assistance.

نویسندگان

  • Einly Lim
  • Socrates Dokos
  • Robert F Salamonsen
  • Franklin L Rosenfeldt
  • Peter J Ayre
  • Nigel H Lovell
چکیده

Numerical models, able to simulate the response of the human cardiovascular system (CVS) in the presence of an implantable rotary blood pump (IRBP), have been widely used as a predictive tool to investigate the interaction between the CVS and the IRBP under various operating conditions. The present study investigates the effect of alterations in the model parameter values, that is, cardiac contractility, systemic vascular resistance, and total blood volume on the efficiency of rotary pump assistance, using an optimized dynamic heart-pump interaction model previously developed in our laboratory based on animal experimental measurements obtained from five canines. The effect of mean pump speed and the circulatory perturbations on left and right ventricular pressure volume loops, mean aortic pressure, mean cardiac output, pump assistance ratio, and pump flow pulsatility from both the greyhound experiments and model simulations are demonstrated. Furthermore, the applicability of some of the previously proposed control parameters, that is, pulsatility index (PI), gradient of PI with respect to pump speed, pump differential pressure, and aortic pressure are discussed based on our observations from experimental and simulation results. It was found that previously proposed control strategies were not able to perform well under highly varying circulatory conditions. Among these, control algorithms which rely on the left ventricular filling pressure appear to be the most robust as they emulate the Frank-Starling mechanism of the heart.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical optimization studies of cardiovascular-rotary blood pump interaction.

A heart-pump interaction model has been developed based on animal experimental measurements obtained with a rotary blood pump in situ. Five canine experiments were performed to investigate the interaction between the cardiovascular system and the implantable rotary blood pump over a wide range of operating conditions, including variations in cardiac contractility and heart rate, systemic vascul...

متن کامل

Serum lactate as a prognostic factor in coronary artery bypass graft operation by on pump method

Background: Lactic acidosis in cardiac surgical patients is a manifestation of systemic inflammation and excess pro-inflammatory cytokine production. This investigation was designed to integrate basic concepts about lactate acidosis with a clinically used of serum lactate in patients under coronary artery bypass surgery (CABG) by on pump method. Methods: From August to September 2012, 15 patie...

متن کامل

Noninvasive average flow estimation for an implantable rotary blood pump: a new algorithm incorporating the role of blood viscosity.

The effect of blood hematocrit (HCT) on a noninvasive flow estimation algorithm was examined in a centrifugal implantable rotary blood pump (iRBP) used for ventricular assistance. An average flow estimator, based on three parameters, input electrical power, pump speed, and HCT, was developed. Data were collected in a mock loop under steady flow conditions for a variety of pump operating points ...

متن کامل

Numerical Simulation of Cavitation in Mixed Flow Pump

The purpose of this study is to investigate the performance and three-dimensional behavior of the flow in a mixed flow pump and the way cavitation phenomenon is affected by different parameters such as fluid temperature, pump speed and flow rate. Computational fluid dynamic software FLUENT 6.3 was utilized to simulate the whole flow field of the pump. RNG k-ε model combined with standard wall f...

متن کامل

The parametric study of an electrical submersible pump rotary gas separator under two-phase flow condition

The performance of the electric submersible pump (ESP) significantly affected by Gas Void Fraction (GVF). Thus, using of a Rotary Gas Separator (RGS) is a suitable solution for this issue. The performance of the RGS is function of different parameters such as geometry of impeller, rotating speed, boundary conditions, media viscosity and GVF. In this study, the influences of GVF, viscosity, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Artificial organs

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2012