Incidence and clinical course of thrombus formation on atrial septal defect and patient foramen ovale closure devices in 1,000 consecutive patients.

نویسندگان

  • Ulrike Krumsdorf
  • Stefan Ostermayer
  • Kai Billinger
  • Thomas Trepels
  • Elisabeth Zadan
  • Kathrin Horvath
  • Horst Sievert
چکیده

OBJECTIVES The purpose of this study was to investigate the incidence, morphology, and clinical course of thrombus formation after catheter closure of intra-atrial shunts. BACKGROUND Post-procedure detailed information about thrombotic material on different devices for transcatheter closure is missing. METHOD A total of 1,000 consecutive patients were investigated after patent foramen ovale (PFO) (n = 593) or atrial septal defect (ASD) (n = 407) closure. Transesophageal echocardiography (TEE) was scheduled after four weeks and six months. Additional TEEs were performed as clinically indicated. RESULTS Thrombus formation in the left atrium (n = 11), right atrium (n = 6), or both (n = 3) was found in 5 of the 407 (1.2%) ASD patients and in 15 of the 593 (2.5%) PFO patients (p = NS). The thrombus was diagnosed in 14 of 20 patients after four weeks and in 6 of 20 patients later on. The incidence was: 7.1% in the CardioSEAL device (NMT Medical, Boston, Massachusetts); 5.7% in the StarFLEX device (NMT Medical); 6.6% in the PFO-Star device (Applied Biometrics Inc., Burnsville, Minnesota); 3.6% in the ASDOS device (Dr. Ing, Osypka Corp., Grenzach-Wyhlen, Germany); 0.8% in the Helex device (W.L. Gore and Associates, Flagstaff, Arizona); and 0% in the Amplatzer device (AGA Medical Corp., Golden Valley, Minnesota). The difference between the Amplatzer device on one hand and the CardioSEAL device, the StarFLEX device, and the PFO-Star device on the other hand was significant (p < 0.05). A pre-thrombotic disorder as a possible cause of the thrombus was found in two PFO patients. Post-procedure atrial fibrillation (n = 4) and persistent atrial septal aneurysm (n = 4) had been found as significant predictors for thrombus formation (p < 0.05). In 17 of the 20 patients, the thrombus resolved under anticoagulation therapy with heparin or warfarin. In three patients, the thrombus was removed surgically. CONCLUSIONS The incidence of thrombus formation on closure devices is low. The thrombus usually resolves under anticoagulation therapy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence of thrombus formation on the CardioSEAL and the Amplatzer interatrial closure devices.

Transcatheter closure for atrial septal defect (ASD) and patent foramen ovale (PFO) is a promising alternative to surgical closure or anticoagulant therapy. A potential complication is thrombus formation on the device after implantation. From February 2001 to June 2003, 66 patients with atrial communication were treated successfully with the Amplatzer device (16 septal and 20 PFO occluders) or ...

متن کامل

Selecting the optimal closure device in patients with atrial septal defects and patent foramen ovaleD

Patent foramen ovale and atrial septal defects are common cardiac defects that can be routinely closed with transcatheter devices, rather than more invasive open surgical techniques. There is good evidence supporting both surgical and transcatheter closure of atrial septal defects, but there remains controversy regarding some of the currently applied indications for patent foramen ovale closure...

متن کامل

Thrombus formation on intracardiac devices: a complex issue.

n a recent issue of the Journal, Krumsdorf et al. (1) iscussed the incidence of thrombus formation on atrial eptal defect (ASD) and patent foramen ovale (PFO) losure devices in 1,000 consecutive patients. The investiators report a group of 593 patients with PFO but only 235 atients had an embolic event. Closure of a PFO is usually ndicated if there is a spontaneous or provokable right-toeft shu...

متن کامل

Risk of thrombus formation on devices used to close transcatheter atrial septal defect and patent foramen ovale.

n a recent issue of the Journal, Krumsdorf et al. (1) iscussed the incidence of thrombus formation on atrial eptal defect (ASD) and patent foramen ovale (PFO) losure devices in 1,000 consecutive patients. The investiators report a group of 593 patients with PFO but only 235 atients had an embolic event. Closure of a PFO is usually ndicated if there is a spontaneous or provokable right-toeft shu...

متن کامل

فراوانی آنومالی های سپتوم بین دهلیزی در بیماران با حوادث آمبولیک مغزی با علت ناشناخته با اکوکاردیوگرافی ترانس توراسیک و ترانس ازوفاژیال، بیمارستان امام تهران

Atrial septal anomalies suggested to play important role in enhancing tendency to induce cerebral embolic events. This study was undertaken to find the frequency of atrial septal anomalies including Patent Foramen Ovale, Atrial Septal Aneurysm and Atrial Septal Defect in patients with etiologically unknown stroke categorized as cryptogenic.Materials and Methods: 32 patients were studied by tran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 2004