Stereoscopic Accuracy

نویسندگان

  • B. Arias
  • J. Gomez
چکیده

In the generation of photogrammetric products with large terrain coverage (Orthophoto, DTMs) some crucial issues like the application of DG / ISO procedures, the management of high amounts of data or the efficiency of automatic measurement (matching) arise. Nevertheless, in spite of the acknowledged progress in this matter, there are still some other relevant tasks like the map plotting that still require a great deal of work and that still are far away from a complete automatic flow. In order to analyze the stereoscopic accuracy (both horizontal and vertical), a measuring test has been performed with different image scales (GSD of 7.5 – 10 cm, 45 – 50 cm). These measures have been realized with digital workstations (Digi3D) and analytical plotters (LeicaSD2000). We have worked with a large number of stereoplotter operators from both public and private companies. We have analyzed the planimetric accuracy which depends on the image scale and also the height accuracy which depends on the image scale and also on the base / height ratio.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stereoscopic X-ray imaging, cone beam CT, and couch positioning in stereotactic radiotherapy of intracranial tumors: preliminary results from a cross-modality pilot installation

BACKGROUND To assess the accuracy and precision of a fully integrated pilot installation of stereoscopic X-ray imaging and kV-CBCT for automatic couch positioning in stereotactic radiotherapy of intracranial tumors. Positioning errors as detected by stereoscopic X-ray imaging are compared to those by kV-CBCT (i.e. the accuracy of the new method is verified by the established method), and repeat...

متن کامل

Stereoscopic vision display technology in real-time three-dimensional echocardiography-guided intracardiac beating-heart surgery.

OBJECTIVE Stereoscopic vision display technology has been shown to be a useful tool in image-guided surgical interventions. However, the concept has not been applied to 3-dimensional echocardiography-guided cardiac procedures. We evaluated stereoscopic vision display as an aid for intracardiac navigation during 3-dimensional echocardiography-guided beating-heart surgery in a model of atrial sep...

متن کامل

E ects of Camera Alignment Errors on StereoscopicDepth

We present in this paper a new analysis of relative sensitivity/importance of camera calibra-tion/alignment parameters on the performance of stereoscopic depth reconstruction. For a given stereoscopic vision system, once stereo correspondence is successfully established, the accuracy of 3D measurements depends on the overall geometric structure of the model in relation to object distances. The ...

متن کامل

Towards a Clinical Stereoscopic Augmented Reality System for Laparoscopic Surgery

We describe our development of a complete real-time stereoscopic augmented reality system that overlays laparoscopic ultrasound (LUS) images on stereoscopic laparoscopic video for conventional laparoscopic surgery. The system was designed and developed to achieve near-term clinical evaluation as a primary goal. Special consideration was paid to system interactivity, accuracy and easy integratio...

متن کامل

Bundle Adjustment for Stereoscopic 3D

The recent resurgence of stereoscopic 3D films has triggered a high demand for post-processing tools for stereoscopic image sequences. Camera motion estimation, also known as structure-from-motion (SfM) or match-moving, is an essential step in the post-processing pipeline. In order to ensure a high accuracy of the estimated camera parameters, a bundle adjustment algorithm should be employed. We...

متن کامل

Patient specific methods for room‐mounted x‐ray imagers for monoscopic/stereoscopic prostate motion monitoring

PURPOSE To investigate the improvement of combined monoscopic/stereoscopic prostate motion monitoring with room-mounted dual x-ray systems by adopting patient specific methods. METHODS The linac couch was used as a motion stage to simulate 40 highly dynamic real patient prostate trajectories. For each trajectory, 40 s pretreatment and 120 s treatment periods were extracted to represent a typi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007