Blood Tracer Kinetics in the Arterial Tree

نویسندگان

  • Elias Kellner
  • Peter Gall
  • Matthias Günther
  • Marco Reisert
  • Irina Mader
  • Roman Fleysher
  • Valerij G. Kiselev
  • Timothy W. Secomb
چکیده

Evaluation of blood supply of different organs relies on labeling blood with a suitable tracer. The tracer kinetics is linear: Tracer concentration at an observation site is a linear response to an input somewhere upstream the arterial flow. The corresponding impulse response functions are currently treated empirically without incorporating the relation to the vascular morphology of an organ. In this work we address this relation for the first time. We demonstrate that the form of the response function in the entire arterial tree is reduced to that of individual vessel segments under approximation of good blood mixing at vessel bifurcations. The resulting expression simplifies significantly when the geometric scaling of the vascular tree is taken into account. This suggests a new way to access the vascular morphology in vivo using experimentally determined response functions. However, it is an ill-posed inverse problem as demonstrated by an example using measured arterial spin labeling in large brain arteries. We further analyze transport in individual vessel segments and demonstrate that experimentally accessible tracer concentration in vessel segments depends on the measurement principle. Explicit expressions for the response functions are obtained for the major middle part of the arterial tree in which the blood flow in individual vessel segments can be treated as laminar. When applied to the analysis of regional cerebral blood flow measurements for which the necessary arterial input is evaluated in the carotid arteries, present theory predicts about 20% underestimation, which is in agreement with recent experimental data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simplified Dynamic Phantom for Pediatric Renography: A Description of Instrument and Its Performance

Objective(s): Renography is used for the diagnostic evaluation of pediatric patients with a suspected obstruction of urinary tract or impaired renal function. The recommended dose for children have been released by the European Association of Nuclear Medicine, Society of Nuclear Medicine and Molecular Imaging, and Japanese Society of Nuclear Medicine. Since acquisition counts in dynamic scintig...

متن کامل

Whole-Body Distribution of Donepezil as an Acetylcholinesterase Inhibitor after Oral Administration in Normal Human Subjects: A 11C-donepezil PET Study

Objective(s): It is difficult to investigate the whole-body distribution of an orally administered drug by means of positron emission tomography (PET), owing to the short physical half-life of radionuclides, especially when 11C-labeled compounds are tested. Therefore, we aimed to examine the whole-body distribution of donepezil (DNP) as an acetylcholinesterase inhibitor by means of 11C-DNP PET ...

متن کامل

Assessment of mediastinal tumors using SUVmax and volumetric parameters on FDG PET/CT

Objective(s): This study aimed to evaluate the role of pretreatment SUVmax and volumetric FDG positron emission tomography (PET) parameters in the differentiation between benign and malignant mediastinal tumors. In addition, we investigated whether pretreatment SUVmax and volumetric FDG-PET parameters could distinguish thymomas from thymic carcinomas, and low-risk from high-risk thymomas.Method...

متن کامل

Hepatic uptake and metabolism of galactose can be quantified in vivo by 2-[F]fluoro-2-deoxygalactose positron emission tomography

Sørensen M, Munk OL, Mortensen FV, Olsen AK, Bender D, Bass L, Keiding S. Hepatic uptake and metabolism of galactose can be quantified in vivo by 2-[F]fluoro-2-deoxygalactose positron emission tomography. Am J Physiol Gastrointest Liver Physiol 295: G27–G36, 2008. First published May 15, 2008; doi:10.1152/ajpgi.00004.2008.—Metabolism of galactose is a specialized liver function. The purpose of ...

متن کامل

Hepatic uptake and metabolism of galactose can be quantified in vivo by 2-[18F]fluoro-2-deoxygalactose positron emission tomography.

Metabolism of galactose is a specialized liver function. The purpose of this PET study was to use the galactose analog 2-[(18)F]fluoro-2-deoxygalactose (FDGal) to investigate hepatic uptake and metabolism of galactose in vivo. FDGal kinetics was studied in 10 anesthetized pigs at blood concentrations of nonradioactive galactose yielding approximately first-order kinetics (tracer only; n = 4), i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014