Robust Active Vibration Control of Smart Structures; a Comparison between Two Approaches: μ-Synthesis & LMI-Based Design

نویسندگان

  • Atta Oveisi
  • Mohammad Gudarzi
چکیده

The purpose of this paper is comparing the performance of two robust control designing approaches in smart structures. First, an accurate model of a homogeneous plate with special boundary conditions is derived by using of modal analysis. Then, some primitive p late’s modes are considered as nominal system and the remaining modes are left as a multip licat ive unstructured modelling uncertainty. Next, two robust controller are designed using μ-Synthesis & LMI-Based Design approaches based on the augmented plant composed of the nominal model and its accompanied uncertainty. Finally, the robustness of two uncertain closed-loop models and the d ifference between two controller performances has been investigated. Obtained results show the higher performance of LMI-Based Design approach in rejection of random disturbances.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Field Programmable Gate Array Implementation of Active Control Laws for Multi-mode Vibration Damping

This paper investigate the possibility and effectiveness of multi-mode vibration control of a plate through real-time FPGA (Field Programmable Gate Array) implementation. This type of embedded system offers true parallel and high throughput computation abilities. The control object is an aluminum panel, clamped to a Perspex box’s upper side. Two types of control laws are studied. The first belo...

متن کامل

Vibration Control of Piezoelectric Flexible Structure Using Robust Control Methodology

Active vibration control of a smart flexible cantilever beam was studied by using mode theory and μ synthesis method. The actuator is piezoceramic patch, the sensor is strain gauge. The finite element method and experimental modal test was applied to obtain the dynamic model of the smart structure. Taking account into uncertainty of the external disturbance and measurement noise, and uncertaint...

متن کامل

A magnetorheological fluid damper for robust vibration control of flexible rotor-bearing systems: A comparison between sliding mode and fuzzy approaches

Squeeze Film Dampers (SFD) are commonly used for passive vibration control of rotor-bearing systems. The Magnetorheological (MR) and Electrorheological (ER) fluids in SFDs give a varying damping characteristic to the bearing that can provide active control schemes for the rotor-bearing system. A common way to model an MR bearing is implementing the Bingham plastic model. Adding this model to th...

متن کامل

Active vibration control of smart building frames by feedback controllers

In this paper the active vibration control of a four-story shear frame instrumented with piezoelectric actuators is presented. The piezoelectric actuators are hosted on the columns in two manners and the produced controlling forces by actuators are considered in the equation of motion. The smart structure modeling and control design is carried out using MATLAB software in state space form. Subs...

متن کامل

Semi-Active Pulse-Switching SSDC Vibration Suppression using Magnetostrictive Materials

One of the best vibration control methods using smart actuators are semi-active approaches which are as strong as active methods and need no external energy supply such as passive ones. Compared with piezoelectric-based, magnetostrictive-based control methods have higher coupling efficiency, higher Curie temperature, higher flexibility to be integrated with curved structures and no depolarizati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013