Mechanical consequences of different scenarios for simulated bone atrophy and recovery in the distal radius.

نویسندگان

  • W Pistoia
  • B van Rietbergen
  • P Rüegsegger
چکیده

Metabolic bone diseases such as osteoporosis usually cause a decrease in bone mass and a deterioration of bone microarchitecture leading to a decline in bone strength. Methods to predict bone strength in patients are currently based on bone mass only. It has been suggested that an improved prediction of bone strength might be possible if structural changes are taken into account as well. In this study we evaluated which structural parameters (other than bone mass) are the best predictors for changes in bone mechanical properties of the human radius after different bone atrophy scenarios and whether the original strength of the affected bone can be recovered if bone loss is restored by thickening of the remaining structures. To answer these questions, a human radius was measured with a microcomputer tomography scanner to extract the full three-dimensional architecture of the distal radius at an isotropic resolution of 80 microm. Eight models with modified bone architecture were created and the mechanical variations due to these modifications were studied using microfinite element (micro-FE) simulations. In four models mass was lowered by 20%, either by reducing cortical thickness, trabecular thickness, or number of trabeculae or by overall thinning of structures. In the other four models bone mass was restored to the original value using a trabecular bone thickening procedure. The micro-FE analyses revealed that most load was carried by the cortical bone. For this reason, bone strength was affected most in the reduced cortical thickness model. For the same reason, the trabecular bone atrophy scenarios, all of which affected bone strength in a very similar way, resulted in less dramatic bone strength reduction. The restoration of bone mass did not recover the original bone strength. These findings demonstrate that the importance of different parameters for the prediction of bone strength also depends on the mechanical loading. This could explain why results of earlier studies on the importance of structural parameters can be inconsistent and site-dependent.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Bone Mineral Density and Serum Vitamin D with Low Energy Hip and Distal Radius Fractures: A Case-Control Study

  Background: The main purpose of this study was to determine the relationship between serum vitamin D and the status of bone mineral density in patients with low-energy hip and distal radius fracture. Methods: This retrospective case-control study was performed between January 2013 and January 2014. Participants aged 55 years or older were divided to case group including 85 patients with lo...

متن کامل

Economic Analysis of the Cost of Implants Used for Treatment of Distal Radius Fractures

Background: There are a number of different implant choices for surgical treatment of distal radius fractures, oftendetermined by surgeon preference or availability. Although no one volar plate demonstrates superior outcomes, thereare significant cost differences absorbed by hospitals and surgical centers. This purpose of this study is to characterizethe economic implications of implant selecti...

متن کامل

Evaluation of one third of distal radius bone density in patients with primary osteoporosis

Background: Osteoporosis is the most common metabolic disease of the bone in the world, and has hit about 200 million people around the world and it increases the risk of fractures. More than 5 million osteoporotic fractures occur annually in the world. Bone mineral density is the standard method of diagnosis of this disease. In this method, proximal of femur (neck) and lumbar vertebra bones (L...

متن کامل

Short-term Results of Using Injectable Bone Cement Technique in the Treatment of Unstable Distal Radius Fractures

Background & Aims: Treatment of osteoporotic distal radius fracture with metaphyseal defect is often complicated by secondary displacement, because of posterior cortex comminution. The aim of this study was to investigate functional outcomes and advantages of injection of bone cement in stabilizing and maintaining this fracture reduction. Methods: This prospective study was performed on 20 ...

متن کامل

Economic Analysis of Bisphosphonate Use after Distal Radius Fracture for Prevention of Hip Fracture

Background: Osteoporosis is a common condition among the elderly population, and is associated with an increased risk of fracture. One of the most common fragility fractures involve the distal radius, and are associated with risk of subsequent fragility fracture. Early treatment with bisphosphonates has been suggested to decrease the population hip fracture burden. However, there have been no p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Bone

دوره 33 6  شماره 

صفحات  -

تاریخ انتشار 2003