Inaccuracies in measurement of contact pressure due to the measuring grid of a foil sensor

نویسندگان

  • Klaus Hoffmann
  • Klaus Decker
چکیده

The measurement of contact stresses between elastic bodies is of great importance in a wide range of fields. Many methods are based on a sensor sheet which is placed between the bodies in contact. Depending on the application, the accuracy of measuring results can be considerably affected by the finite thickness and structure of the inserted sensor. This study deals with the imprecision of the Tekscan system and attempts to explain the cause of deviations. For this purpose an imprint method using Fuji prescale film/GODAV software and the FE method was used to compare the results with the results of the Tekscan system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Optical Measurement System to Measure Velocity and Provide Shock Wave Pressure Diagrams

This paper introduces an optical measurement system for shock wave characteristics. The system works by mountinga metal plate attached to spring mounts against the shock wavefront. This set is sealed and can plot the shock wave pressure diagram by measuring plate's displacement, radiation and changing the reflection of light during shock wave conflict, and converting these optical data to volta...

متن کامل

Design, Modeling, and Construction of a New Tactile Sensor for Measuring Contact-Force

This paper presents the design, modeling, and testing of a flexible tactile sensor and its applications. This sensor is made of polymer materials and can detect the 2D surface texture image and contact-force estimation. The sensing mechanism is based on the novel contact deflection effect of a membrane. We measure the deflection of the membrane with measuring the strain in the membrane with emb...

متن کامل

A positioning sensor for tonometric applications

In this paper we present a sensor, which is designed for application in a tonometer, an instrument for the measurement of intraocular pressure. The sensor measures diameter and position of a part of the eye globe that is flattened by the tonometer. The sensor principle is based on a change in resistance of four resistor arrays due to contact with a metallized foil, which flattens a part of the ...

متن کامل

Measuring the deposited energy from a non-ionizing laser beam in water by digital holographic interferometry

Digital Holographic interferometry is a powerful and widely used optical technique for accurate measurement of variations in physical quantities such as density, refractive index, and etc. In this study, an experimental digital holographic interferometry setup was designed and used to measure the amount of energy changes induced by absorption of radiation from a non-ionizing infrared laser beam...

متن کامل

Design and Construction of a Novel Tactile Sensor for Measuring Contact-Force, Based on Piezoelectric Effect

In this paper, design and construction of a tactile sensor for measuring contact-force is presented. Mechanism of measuring contact-force in this tactile sensor is based on impedance changing of piezoelectric crystal and voltage of different points in circuit as a result of applying force on the crystal. By considering a specific point in the circuit and recording the changes of its voltage, ma...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IJISTA

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2007