Helical tomotherapy in the radiotherapy treatment of Hodgkin's disease ‐ a feasibility study

نویسندگان

  • Maria T. Vlachaki
  • Sanath Kumar
چکیده

Radiation therapy for advanced Hodgkin's disease often requires large fields and may result in significant exposure of normal tissues to ionizing radiation. In long-term survivors, this may increase the risk for late toxicity including secondary malignancies. 3DCRT has been successfully used to treat this disease but treatment delivery is often complex requiring matching of photon with electron beams, utilization of field-in-field techniques and of partial transmission blocks. HT is an arc-rotational intensity modulated radiation therapy technique proven to achieve superior target dose conformality and sharp dose gradients around critical normal tissues. HT however, has also been associated with higher volumes of low dose regions in normal tissues and therefore, higher integral dose. The present study was undertaken to compare the dosimetry of 3DCRT to HT in a pediatric patient with advanced HD. Clinical target volume (CTV) included bilateral lower cervical and supraclavicular areas, mediastinum, bilateral hili, left axilla and bilateral diaphragmatic lymph nodes. The planning target volume (PTV) was derived by circumferentially expanding the CTV by 1 cm. Whole lung and heart irradiation was also planned due to bilateral pleural and pericardial effusions. The prescribed radiation dose was 21 Gy to the PTV and 10.5 Gy to the whole lung and heart. Target coverage was comparable for both plans. The minimum, maximum and mean PTV doses were 18.61 Gy, 22.45 Gy and 21.52 Gy with 3DCRT and 19.85 Gy, 22.36 Gy and 21.39 Gy with HT, respectively. HT decreased mean normal tissue dose by 21.6% and 20.07% for right and left breast, 20.40% for lung, 30.78% for heart and 22.74% for the thyroid gland. Integral dose also decreased with HT by 46.50%. HT results in significant dosimetric gain related to normal tissue sparing compared to 3DCRT. Further studies are warranted to evaluate clinical applications of HT in patients with HD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Secondary Cutaneous Involvement in Follicular Diffuse Lymphoma Treated with Helical Tomotherapy

Non-Hodgkin's lymphoma is a complex heterogeneous group of disease entities that involves nodal and extranodal tissues. Cutaneous involvement can occur either as a primary or secondary in course of disease. Radiation therapy with either total body or localized treatments is often used for local control and symptom relief, depending on the target volume. We describe a 60-year-old male with a rem...

متن کامل

Analysis of peripheral doses for base of tongue treatment by linear accelerator and helical TomoTherapy IMRT

The purpose of this study was to compare the peripheral doses to various organs from a typical head and neck intensity-modulated radiation therapy (IMRT) treatment delivered by linear accelerator (linac) and helical TomoTherapy. Multiple human CT data sets were used to segment critical structures and organs at risk, fused and adjusted to an anthropomorphic phantom. Eighteen contours were design...

متن کامل

Comparison of survival rates between patients treated with conventional radiotherapy and helical tomotherapy for head and neck cancer

PURPOSE Compared to conventional radiotherapy (RT), intensity-modulated radiotherapy (IMRT) significantly reduces the rate of treatment-induced late toxicities in head and neck cancer. However, a clear survival benefit of IMRT over conventional RT has not yet been shown. This study is among the first comparative study to compare the survival rates between conventional RT and helical tomotherapy...

متن کامل

Clinical evaluation of simultaneous integrated boost in brain metastasis patients with helical intensity modulated radiotherapy

Background: This study was performed to assess patient survival and treatment toxicity after helical tomotherapy (HT) with simultaneous integrated boost (SIB) radiotherapy (RT) for cancer patients with one to eight brain metastases (BM) who have been treated with or without surgery. Materials and Methods: A total of 48 brain metastasis (BM) patients were included in this retrospective study bet...

متن کامل

Selection of the optimal radiotherapy technique for locally advanced hepatocellular carcinoma.

OBJECTIVE Various techniques are available for radiotherapy of hepatocellular carcinoma, including three-dimensional conformal radiotherapy, linac-based intensity-modulated radiotherapy and helical tomotherapy. The purpose of this study was to determine the optimal radiotherapy technique for hepatocellular carcinoma. METHODS Between 2006 and 2007, 12 patients underwent helical tomotherapy for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2010