Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis.

نویسندگان

  • Hasan Jilaihawi
  • Derek Chin
  • Tomasz Spyt
  • Mohamed Jeilan
  • Mariuca Vasa-Nicotera
  • Johan Bence
  • Elaine Logtens
  • Jan Kovac
چکیده

AIMS Prosthesis-patient mismatch (P-PM) is an important determinant of morbidity and mortality following open aortic valve replacement. The aims of this study were to report its incidence and determinants following transcatheter aortic valve implantation (TAVI) with the Corevalve bioprosthesis, which have-thus far-not been described. METHODS AND RESULTS Patients with severe calcific aortic stenosis received TAVI with the Corevalve bioprosthesis via transfemoral route. Following TAVI, moderate P-PM was defined as indexed aortic valve effective orifice area (AVAi) < or =0.85 cm(2)/m(2) and severe P-PM as AVAi < or =0.65 cm(2)/m(2). Clinical, echocardiographic, and procedural factors relating to P-PM were studied. Optimal device position was defined on fluoroscopy as final position of the proximal aspect of the Corevalve stent frame 5-10 mm below the native aortic annulus. Between January 2007 and January 2009, 50 consecutive patients underwent TAVI in a single centre with the Corevalve bioprosthesis. Mean age was 82.8 years (SD 5.9; 70-93) and 48% were male. P-PM occurred in 16 of 50 cases (32%). Optimal position was achieved in 50% of cases. P-PM was unrelated to age, annulus size, LVOT size, Corevalve size, aortic angulation, ejection fraction, and sex. It was inversely correlated to optimal position (Spearman rho r = -0.34, P = 0.015). Those with optimal positioning had a 16% incidence of P-PM relative to 48% of those with suboptimal positioning (Pearson chi(2) P = 0.015). CONCLUSION The incidence of P-PM following TAVI with the Corevalve bioprosthesis is compared favourably with that seen after AVR with conventional open stented bioprostheses and its occurrence is influenced by device positioning.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical Bailout Therapy after Implantation of a Medtronic CoreValve Bioprosthesis

Moderate-to-severe paraprosthesic leak causing hemodynamic deterioration and left ventricular remodeling can occur after transcatheter aortic valve implantation (TAVI). We present the case of a 75-year-old woman who underwent TAVI with a 26 mm CoreValve prosthesis complicated with an acute left ventricle dilatation due to a severe paravalvular leak. Patient was unresponsive to elective balloon ...

متن کامل

Self-expandable transcatheter aortic valve implantation for aortic stenosis after mitral valve surgery.

OBJECTIVES Transcatheter aortic valve implantation has emerged as a valuable option to treat patients with symptomatic severe aortic stenosis, who are not being considered for surgery because of significant comorbidities. Concerns exist over treating patients who have previously undergone mitral valve surgery for possible interference between the percutaneous aortic valve and the mitral prosthe...

متن کامل

Valve-in-valve implantation of Medtronic CoreValve prosthesis in patients with failing bioprosthetic aortic valves.

BACKGROUND Transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve (MCV) system might represent an alternative to conventional redo surgery in older high-risk patients with a failing aortic valve bioprosthesis. METHODS AND RESULTS Symptomatic patients with failing aortic valve bioprosthesis, aged ≥65 years with a logistic EuroSCORE ≥10 % were considered for treatment. Loc...

متن کامل

Incidence and management of CoreValve dislocation during transcatheter aortic valve implantation.

BACKGROUND Transcatheter aortic valve implantation is a highly specialized technique offering a new therapeutic option to patients at high risk for conventional surgery. Complications associated with this catheter procedure differ from complications after surgical aortic valve replacement. This is to report incidence, management, and impact on morbidity and mortality of CoreValve dislocation du...

متن کامل

Transcatheter bioprosthesis implantation for the treatment of aortic stenosis: three-year experience.

BACKGROUND Transcatheter aortic bioprosthesis implantation is a new treatment modality for patients with aortic stenosis who are inoperable or at high surgical risk. OBJECTIVE To report the three-year experience with transcatheter CoreValve® bioprosthesis implantation. METHODS From January 2008 to January 2011, 35 patients with aortic stenosis (33) or aortic valve bioprosthesis dysfunction ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European heart journal

دوره 31 7  شماره 

صفحات  -

تاریخ انتشار 2010