Comparison of stromal corneal nerves between normal and keratoconus patients using confocal microscopy.

نویسندگان

  • M Ramírez Fernández
  • E Hernández Quintela
  • R Naranjo Tackman
چکیده

OBJECTIVE To evaluate the differences in stromal corneal nerves between normal patients and keratoconus patients. MATERIAL AND METHODS A total of 140 eyes of 70 normal patients (group A) and 122 eyes of 87 keratoconus patients (group B) were examined with the confocal microscope, with a central scan of the total corneal thickness being taken. The morphology and thickness of the corneal stromal nerves were evaluated by using the Navis v. 3.5.0. software. Nerve thickness was obtained from the mean between the widest and the narrowest portions of each stromal nerve. RESULTS Corneal stromal nerves were observed as irregular linear hyper-reflective structures with wide and narrow portions in all cases. Mean corneal stromal nerves thickness in group A was 5.7±1.7 (range from 3.3 to 10.4 μ), mean corneal stromal nerves thickness in group B was 7.2±1.9 (range from 3.5 to 12.0 μ). There was a statistical significant difference (P<.05) in stromal corneal nerves thickness between group A and group B. CONCLUSION Stromal corneal nerves morphology was similar in both groups, but stromal nerves were thicker in keratoconus patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

corneal confocal microscopic analysis in patients with keratoconus 窑 Clinical Research 窑

· AIM: To quantify corneal ultrastructure using laser scanning confocal microscopy (IVCM) in patients with keratoconus and control subjects. · METHODS: Unscarred corneas of 78 keratoconic subjects without a history of contact lens use and 36 age-matched control subjects were evaluated with slitlamp examination (SLE), corneal topography and laser scanning IVCM. One eye was randomly chosen for an...

متن کامل

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

Corneal Cell Morphology in Keratoconus: A Confocal Microscopic Observation.

PURPOSE To evaluate corneal cell morphology in patients with keratoconus using an in vivo slit scanning confocal microscope. METHODS A cross-sectional study was conducted to evaluate the corneal cell morphology of 47 keratoconus patients and 32 healthy eyes without any ocular disease. New keratoconus patients with different disease severities and without any other ocular co-morbidity were rec...

متن کامل

In vivo confocal microscopy of human corneal nerves in health, in ocular and systemic disease, and following corneal surgery: a review.

The exponential evolution of in vivo confocal microscopy (IVCM) has led to a significant enhancement in our knowledge of the living cornea in both its physiological and pathological states. Studies using white light and coherent light-based IVCM have enabled detailed quantitative analysis of sub-basal nerve parameters, and have also resulted in the elucidation of the two-dimensional architectur...

متن کامل

Evaluation of Corneal Stromal Demarcation Line after Two Different Protocols of Accelerated Corneal Collagen Cross-Linking Procedures Using Anterior Segment Optical Coherence Tomography and Confocal Microscopy

Purpose. To evaluate the depth of corneal stromal demarcation line using AS-OCT and confocal microscopy after two different protocols of accelerated corneal collagen cross-linking procedures (CXL). Methods. Patients with keratoconus were divided into two groups. Peschke CXL device (Peschke CCL-VARIO Meditrade GmbH) applied UVA light with an intended irradiance of 18.0 mW/cm(2) for 5 minutes aft...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archivos de la Sociedad Espanola de Oftalmologia

دوره 89 8  شماره 

صفحات  -

تاریخ انتشار 2014