Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

نویسندگان

  • Antonio Gabriel Lanata-Flores
  • Eder Alberto Sigua-Rodriguez
  • Douglas Rangel Goulart
  • Veber Luiz Bomfim-Azevedo
  • Sergio Olate
  • José Ricardo de Albergaria-Barbosa
چکیده

OBJECTIVES This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. MATERIALS AND METHODS Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. RESULTS The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. CONCLUSION The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rehabilitation of an Auricular Defect Using Surgical Stent

Reconstruction of a facial defect is a complex modality either surgically or prosthetically, depending on the site, size, etiology, severity, age, and the patient’s expectation. Loss of an auricle, in the presence of an auditory canal, affects hearing, because the auricle gathers sound and directs it into the canal. The auricle acts as a resonator to slightly amplify lower frequency sound...

متن کامل

Comparison of "look-alike" implant prosthetic retaining screws.

PURPOSE The maximum preload torque of implant prosthetic retaining screws from four manufacturers and of two alloy types was measured to determine one index of interchangeability of intersystem components. MATERIALS AND METHODS Implant prosthetic retaining screws from four manufacturers (3i Implant Innovations Inc, West Palm Beach, FL; Impla-Med Inc, Sunrise, FL; Nobelpharma USA Inc, Chicago,...

متن کامل

Magnet-retained auricular prosthesis with an implant-supported composite bar: a clinical report.

The use of craniofacial implants to assist in retaining auricular prostheses often requires complex laboratory procedures, involving production of an accurate casting, fitting of a precious alloy bar, and the use of clips. A simplified method for the retention of an auricular prosthesis with a composite bar and magnets is described in this article.

متن کامل

Screw Joint Stability in Conventional and Abutment-Free Implant-Supported Fixed Restorations.

PURPOSE Procera Implant Bridges (PIBs) do not engage supporting implant shoulders and are fixed using comparably long retention screws. The aim of this in vitro clinical study was to determine the detorque values in PIBs and conventionally fabricated fixed dental prostheses (FDPs). MATERIALS AND METHODS Two groups of screw-retained implant-supported three-unit FDPs (n=10) were fabricated by m...

متن کامل

Prosthetic Rehabilitation of Nasal Defect: A Case Report

Abstract Facial defects not only impact on the function and quality of life but also affect the psychological well-being and social behavior of patients. A nasal prosthesis can re-establish the esthetics and anatomical contour in patients with mid-facial defects, often more effectively than surgical reconstruction. For successful results, many factors such as retention, texture, color match ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 42  شماره 

صفحات  -

تاریخ انتشار 2016