Analysis of reverse total shoulder joint forces and glenoid fixation.

نویسندگان

  • Young W Kwon
  • Rachel E Forman
  • Peter S Walker
  • Joseph D Zuckerman
چکیده

Reverse total shoulder arthroplasty (rTSA) implants are intended to restore stability and function to shoulders with rotator cuff deficiency. The implant consists of a glenosphere projecting from a glenoid baseplate and articulating in a socket at the proximal end of a humeral component. Despite the demonstrated clinical efficacy, little information is available regarding the joint forces about this construct and the stability of the glenoid component against these forces. Our hypotheses were that the joint forces about the rTSA were comparable to that about a normal shoulder joint, and that the micromotion between the baseplate and the scapula against these loads would be sufficiently low to induce bone ingrowth. To investigate this, a custom testing rig was constructed to simulate active shoulder elevation in fresh-frozen shoulder specimens. The forces about the rTSA were calculated and found to include compressive and shear forces up to 0.7 and 0.4 BW, respectively. In contrast to a normal shoulder, where the joint forces peak at 90° of abduction, forces about the rTSA were highest at about 60° of abduction. These forces were then applied in cyclic loading conditions to the glenoid baseplate, and the micromotion of the implant relative to the bone was measured in the four quadrants of the component. For two different rTSA designs (DePuy Delta III® and Encore RSP®) and in the entire range of the fixation testing, the cyclical micromotions were always less than 62 µm. Thus, under loading conditions similar to physiological shoulder elevation, micromotion of the glenoid component was sufficiently low and within previously published limits to induce bone ingrowth.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Initial Fixation of the Trabecular Metal Reverse Shoulder Glenoid Base Plate Implant

Background Reverse total shoulder arthroplasty is an increasingly utilized treatment option for glenohumeral arthritis with massive, irreparable rotator cuff disruption associated with loss of glenohumeral stability and function. Several reverse shoulder implant designs from different manufacturers have been introduced to the market in recent years. Fixation of the glenoid base plate has been s...

متن کامل

Addressing glenoid erosion in reverse total shoulder arthroplasty.

Severe glenoid wear is technically problematic, has a higher complication rate, and inferior results in the setting of shoulder arthroplasty. This paper introduces four basic strategies for treating glenoid erosion with a reverse shoulder arthroplasty which include; 1. eccentric reaming, 2. bone grafting of glenoid, 3. reaming and bone grafting, and 4. using augmented baseplates. The benefits a...

متن کامل

Revision of Anatomic Total Shoulder Arthroplasty to Hemiarthroplasty: Does it work?

Background: The projected increase in revision shoulder arthroplasty has increased interest in the outcomes of theseprocedures. Glenoid component removal and conversion to a hemiarthroplasty (HA) is an option for aseptic glenoidloosening after anatomic total shoulder arthroplasty (aTSA).Methods: We identified patients who had undergone revision shoulder arthroplasty over a 15-...

متن کامل

Reverse Total Shoulder Arthroplasty With Humeral Head Autograft Fixed Onto Glenoid for Treatment of Severe Glenoid Retroversion

Advanced glenohumeral osteoarthritis can transform glenoid morphology and, in some cases, is found in association with severe glenoid retroversion. The associated glenoid retroversion leads to difficulty in fixation of the glenoid component in reverse total shoulder arthroplasty. In the context of extreme glenoid wear, structural grafts can be used to restore glenoid volume and version in order...

متن کامل

Influence of peg design and cement mantle thickness on pull-out strength of glenoid component pegs.

Fixation of the glenoid component is critical to the outcome of total shoulder arthroplasty. In an in vitro study, we analysed the effect of surface design and thickness of the cement mantle on the pull-out strength of the polyethylene pegs which are considered essential for fixation of cemented glenoid components. The macrostructure and surface of the pegs and the thickness of the cement mantl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Bulletin of the NYU hospital for joint diseases

دوره 68 4  شماره 

صفحات  -

تاریخ انتشار 2010