Laboratory assessment of a commercial kit for measuring fructosamine in serum.

نویسندگان

  • D R Jury
  • P J Dunn
چکیده

We have evaluated the laboratory performance and clinical usefulness of the Roche fructosamine kit. As used with an Abbott ABA 100 bichromatic analyzer, the kit response varied linearly with fructosamine concentration to 5.0 mmol/L (deoxymorpholinofructose equivalents). Interbatch precision was 4.1% and 3.6% for respective fructosamine concentrations of 3.2 and 5.0 mmol/L; intrabatch precision was 3.2% and 3.0% (fructosamine = 3.0 and 4.0 mmol/L). In 55 nondiabetic subjects all fructosamine values were less than 3.0 mmol/L, 95% were less than 2.7 mmol/L. For both fructosamine and glycated hemoglobin (Hb A1c) the 95th percentile of the reference range corresponded to approximately the 10th percentile of values observed in 108 diabetic subjects. In the latter subjects fructosamine concentrations correlated somewhat (r = 0.6504) with the Hb A1c value and for eight diabetic subjects indicated a similar degree of diabetic control over a 10-week period. From assessments of sensitivity and specificity for predicting abnormal glucose tolerance in 145 subjects, we conclude that this assay of serum fructosamine reflects diabetic control about as well as Hb A1c estimation, but neither can replace the glucose tolerance test for the diagnosis of diabetes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative potency of commercial calibrators for fructosamine, and their effect on measurements of fructosamine in serum.

The protein-based secondary standardsfor serum fructosamine in a commercial test kit (Roche Diagnostics) have recently been modified by the manufacturer. Under certain assay conditions, the new calibrator gave significantly greater serum fructosamine values than those obtained with the originally supplied calibrator. However, for 20-4, samples and absorbance measurements at 10 and 15 mm, hereaf...

متن کامل

Evaluationof a Single-Color-ReadingMethod for DeterminingFructosamine MurrayA. Rosenthal’ and Unda

A commercial kit fordetermining fructosamine was evaluated. The reference interval (determined from data on 183 nondiabetic subjects) was 1.67 to 2.85 (mean 2.17) mmol/L. Serum and plasma (EDTAor heparin-anticoagulated) gave equivalent results; plasma treated with fluoride/oxalate gave slightly lower values. The between-run CV was <4%. Fructosamine values were similar by the present method and ...

متن کامل

Comparison of Two ELISA Methods for the Laboratory Diagnosis of Acute Leptospirosis

Background: Leptospirosis is the most common zoonosis widespread in tropical and temperate countries with low social-economic status. We aimed to compare an ELISA kit with an in-house ELISA assay to test the serum samples of the patients who were suspicious of leptospirosis according to their clinical symptoms. Methods: A total of 282 serum samples of patients suspicious of leptospirosis admitt...

متن کامل

Diagnostic Value of Fructosamine and Glycosylated Hemoglobin in Estimating Blood Glucose Level in Diabetic Patients with Thalassemia Major

Abstract Background and Objective: Diabetes mellitus is one of complications that thalassemia major patients face with. Hence, blood glucose monitoring is of vital importance to these patients. Because of high level of fetal hemoglobin in these patients, the measurement of hemoglobin A1c is not reliable and should be displaced by fructosamine test. Material and Methods: The current descr...

متن کامل

Fructosamine and glycated hemoglobin in the assessment of glycaemic control in dogs.

Fructosamine and glycated hemoglobin (HbA1c) concentrations were measured simultaneously in 222 dogs (96 healthy and 126 sick dogs). The dogs were divided into 3 groups according to the glucose concentration: hypo, hyper and euglycaemic dogs. Serum fructosamine concentrations were measured by the reduction test with nitroblue tetrazolium. A turbidimetric inhibition immunoassay and specific poly...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 33 1  شماره 

صفحات  -

تاریخ انتشار 1987