A simple, reliable method for the determination of chlorinated volatile organics in human breath and air using glass sampling tubes.

نویسندگان

  • V B Stein
  • R S Narang
  • L Wilson
  • K M Aldous
چکیده

A method for determining chloroform, 1,1,1-trichloroethane, carbon tetrachloride, and trichloroethene in breath samples was developed. It consisted of collecting samples in 40-ml. glass-silanized tubes that were 16-in. long and had a 0.64-in. diameter. The ends tapered, resulting in a tube with a 1/4-in. diameter that was 1 3/4-in. long; each end had a shutoff valve attached. One end had a strip of rubber tube attached to the shutoff valve for collecting the breath sample, and the other end contained a 1/4-in. Swagelok nut with a rubber septum for withdrawing the sample. Samples were withdrawn using a pressure-lock, gastight syringe, and they were injected onto a gas chromatograph fitted with an electron-capture detector. The analytes were stable for at least 22 days in these tubes. The method detection limit was determined to be 0.03, 0.08, 0.04, and 0.04 pg/ml. for chloroform, 1,1,1-trichloroethane, carbon tetrachloride, and trichloroethene, respectively. Precision, based on 13 injections, was determined to be 13% for 0.09 pg chloroform, 13% for 0.21 pg 1,1,1-trichloroethane, 8% for 0.16 pg carbon tetrachloride, and 14% for 0.1 pg trichloroethene. In all, the proposed method is a sensitive and reliable one for determining volatile organic compounds in breath and a method that can also be applied to air sampling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast and Sensitive Determination of Acetic Anhydride in the Air Using Hollow Fiber Method

This study aimed to introduce a new method based on Hollow Fiber in order to determination of acetic anhydride (AA) in the air. Hydroxylamine hydrochloride and sodium hydroxide (1:1), were used as extraction solvent. This method was studied in the laboratory under various conditions. In order to make different concentrations of AA in the air, a standard glass chamber was used. The optimization ...

متن کامل

Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review

Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...

متن کامل

Development of a Method Based on the Needle-trap Microextraction Filled with Hydroxyapatite and Polyaniline Nanocomposite for Determination of Volatile Organic Compounds in the Air

In this study, the efficiency of packed needle trap with hydroxyapatite/polyaniline (NTD-HAP/PA) nanocomposite was assessed in air sampling and analysis of a hazardous group of VOCs such as benzene, toluene, ethylbenzene and xylenes. The effects of main parameters, including desorption temperature and time, were evaluated on the performance and carryover of prepared NTDs. Moreover, the repeatab...

متن کامل

Optimisation of sampling parameters for standardised exhaled breath sampling.

The lack of standardisation of breath sampling is a major contributing factor to the poor repeatability of results and hence represents a barrier to the adoption of breath tests in clinical practice. On-line and bag breath sampling have advantages but do not suit multicentre clinical studies whereas storage and robust transport are essential for the conduct of wide-scale studies. Several device...

متن کامل

A field method for sampling toluene in end-exhaled air, as a biomarker of occupational exposure: correlation with other exposure indices.

A sensitive and rapid method for the determination of toluene in exhaled air is described. We have developed a device for direct breath sampling consisting of a sampler inserted into an empty 58 mL glass vial closed by a Teflon rubber septum. The sorbent cartridge functions as a diffusive sampler and employs a Tenax resin (300 mg, 35/50 mesh) to trap volatile organic compounds from the exhaled ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 1996