Local thickness measurement through scattering contrast and electron energy-loss spectroscopy.
نویسندگان
چکیده
Scattering contrast measurements were performed on thin films of amorphous carbon and polycrystalline Au, as well as single-crystal MgO nanocubes. Based on the exponential absorption law, mass-thickness can be obtained within 10% accuracy by measuring the incident and transmitted intensities in the same image. For mass-thickness measurement of a thin amorphous specimen, a small collection semiangle improves the measurement sensitivity, whereas for the measurement of polycrystalline or single-crystal specimens, a large collection semiangle should be used to reduce diffraction-contrast effects. EELS thickness measurements on MgO nanocubes suggest that the Kramers-Kronig sum-rule method (with correction for plural and surface scattering) gives 10% accuracy at medium collection semiangles but overestimates the thickness at small collection semiangles, due to underestimation of the surface-mode scattering. The log-ratio method, with a formula for inelastic mean free path proposed by Malis et al. (1988), provides 10% accuracy at small collection semiangle, while that proposed by Iakoubovskii et al. (2008a) is preferable for medium and large collection semiangles. As a result of this work, we provide recommendations of preferred methods and conditions for local-thickness measurement in the TEM.
منابع مشابه
Electron energy-loss spectroscopy in the TEM
Electron energy-loss spectroscopy (EELS) is an analytical technique that measures the change in kinetic energy of electrons after they have interacted with a specimen. When carried out in a modern transmission electron microscope, EELS is capable of giving structural and chemical information about a solid, with a spatial resolution down to the atomic level in favourable cases. The energy resolu...
متن کاملSpin polarized transport in semiconductors – Challenges for Na
Organic thin-film devices are rapidly developing and a routine method of measuring the thickness of an organic film is desirable, particularly if this enables the measurement of local thickness with good spatial resolution. Techniques that employ a transmission electron microscope (TEM) are attractive, since the spatial resolution can then be as small as 1 nm. Electron energy-loss spectroscopy ...
متن کاملInelastic electron scattering observation using energy filtered transmission electron microscopy for silicon -- germanium nanostructures imaging.
This paper presents a new technique using energy filtered TEM (EFTEM) for inelastic electron scattering contrast imaging of Germanium distribution in Si-SiGe nanostructures. Comparing electron energy loss spectra (EELS) obtained in both SiGe and Si single crystals, we found a spectrum area strongly sensitive to the presence of Ge in the range [50-100 eV]. In this energy loss window, EELS spectr...
متن کاملFour-dimensional dielectric property image obtained from electron spectroscopic imaging series.
We have demonstrated a new quantitative method to characterize two-dimensional distributions of energy-dependent dielectric function of materials from low loss electron spectroscopic image (ESI) series. Two problems associated with extracted image-spectrum from the low-loss image series, under-sampling and loss of energy resolution, were overcome by using fast Fourier transformation (FFT) inter...
متن کاملAnalysis at the Atomic Level: The Atom Probe Field-Ion Microscope
Figure 2. Angular distributions of inelastic scattering around the undiffracted beam and around a beam diffracted through an angle a. The shaded area represents the contribution from the diffracted beam to the intensity collected by an on-axis aperture of semi-angle A3. [6] Egerton, R. F., Electron Energy Loss Spectroscopy in the Electron Microscope, Plenum Press, New York (1986). [7] Steele, J...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Micron
دوره 43 1 شماره
صفحات -
تاریخ انتشار 2012