Mass and Charge Measurements on Heavy Ions

نویسنده

  • Toshiki Sugai
چکیده

The relationship between mass and charge has been a crucial topic in mass spectrometry (MS) because the mass itself is typically evaluated based on the m/z ratio. Despite the fact that this measurement is indirect, a precise mass can be obtained from the m/z value with a high m/z resolution up to 105 for samples in the low mass and low charge region under 10,000 Da and 20 e, respectively. However, the target of MS has recently been expanded to the very heavy region of Mega or Giga Da, which includes large particles and biocomplexes, with very large and widely distributed charge from kilo to Mega range. In this region, it is necessary to evaluate charge and mass simultaneously. Recent studies for simultaneous mass and charge observation and related phenomena are discussed in this review.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

02 v 1 1 1 O ct 1 99 5 A PROCEDURE TO CALIBRATE A MULTI - MODULAR TELESCOPE

A procedure has been developed for the charge, mass and energy calibration of ions produced in nuclear heavy ion reactions. The charge and mass identification are based on a ∆E-E technique. A computer code determines the conversion from ADC channels into energy values, atomic number and mass of the detected fragments by comparing with energy loss calculations through a minimization routine. The...

متن کامل

The Temperature and Mass Effects on Dust Grain Electrical Potential in Dusty Plasma

By orbit-limited motion (OLM) theory and the kinetic model, currents carried by electronsand ions on the dust grain are obtained and the effects of temperature and drift velocity of ions on thedust grain electrical potential are considered. The calculations were performed for finding the role of densities of dust grains and ions on the dust grain electrical potential which is the ma...

متن کامل

- ex / 9 80 70 08 v 1 2 9 Ju l 1 99 8 1 Fission fragment mass reconstruction from Si surface barrier detector measurement

A method for plasma delay and pulse-height defect corrections for Si surface barrier detectors (SBD) is presented. Based on known empirical formulae, simple approximations involving the measured time-of-flight (TOF) and energy of the ions were found and a mass reconstruction procedure was developed. The procedure was applied for obtaining the fission fragment mass and angular distributions from...

متن کامل

Modeling Magnetic Field in Heavy ion Collisions Using Two Different Nuclear Charge Density Distributions

By studying the properties of matter during heavy-ion collisions, a better understanding of the Quark-Gluon plasma is possible. One of the main areas of this study is the calculation of the magnetic field, particularly how the values of conductivity affects this field and how the field strength changes with proper time. In matching the theoretical calculations with results obtained in lab, two diffe...

متن کامل

Turbulent transport and heating of trace heavy ions in hot magnetized plasmas.

Scaling laws for the transport and heating of trace heavy ions in low-frequency magnetized plasma turbulence are derived and compared with direct numerical simulations. The predicted dependences of turbulent fluxes and heating on ion charge and mass number are found to agree with numerical results for both stationary and differentially rotating plasmas. Heavy ion momentum transport is found to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2017