New Results for the CZT Drift

نویسندگان

  • I. Kuvvetli
  • C. Budtz-Jørgensen
  • C. M. Stahle
چکیده

The drift strip method for improving the energy response of a CdZnTe (CZT) detector to hard X and gamma rays is discussed. Results for a 10x10x3 mm3 detector crystal demonstrate a remarkable improvement of the energy resolution. The full width at half maximum (FWHM) is 2.18 keV (3.6%), 2.45 keV (3.0%), 2.86 keV (0.8%) and 3.89 keV (0.6%) at 60 keV, 80 keV, 356 keV and 661 keV, respectively. The resolution is limited by electronic noise below 100 keV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system

Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...

متن کامل

New Results from Performance Studies of Frisch-Grid CdZnTe Detectors

New data regarding performance studies of Frisch-grid CdZnTe (CZT) detectors are presented. The Frisch-grid detector configuration under investigation is a bar shaped CZT crystal with the side surfaces coated with an insulating layer. A Frisch grid is fashioned by inserting the CZT bar into a metallic sleeve, or by depositing the metal directly upon the insulator; hence the semiconductor materi...

متن کامل

CZT imaging detectors for ProtoEXIST

We describe the detector development for a balloon-borne wide-field hard X-ray (20 – 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT dete...

متن کامل

Detecting Concept Drift in Data Stream Using Semi-Supervised Classification

Data stream is a sequence of data generated from various information sources at a high speed and high volume. Classifying data streams faces the three challenges of unlimited length, online processing, and concept drift. In related research, to meet the challenge of unlimited stream length, commonly the stream is divided into fixed size windows or gradual forgetting is used. Concept drift refer...

متن کامل

Absolute Myocardial Blood Flow and Flow Reserve Assessed by Gated SPECT with Cadmium-Zinc-Telluride Detectors Using 99mTc-Tetrofosmin: Head-to-Head Comparison with 13N-Ammonia PET.

Recent advances in SPECT technology including cadmium-zinc-telluride (CZT) semiconductor detector material may pave the way for absolute myocardial blood flow (MBF) measurements by SPECT. The aim of the present study was to compare K1 uptake rate constants as surrogates of absolute MBF and myocardial flow reserve index (MFRi) in humans as assessed with a CZT SPECT camera versus PET. METHODS A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001